Untitled Project
Battery Engineering Platform - Proposed Baseline Rev 0.1
STK-001
1. STK-001 - Stakeholder UID: STK-001 STATUS: Draft DOMAIN: Stakeholder RELATIONS (Child): STATEMENT:

The product shall provide a replaceable 12.8 V nominal rechargeable energy source.

ACCEPTANCE:

4S1P LFP reference architecture reviewed against intended load.

METHOD:

Review

VMODEL_LEVEL:

Validation

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

STK-002
2. STK-002 - Stakeholder UID: STK-002 STATUS: Draft DOMAIN: Stakeholder RELATIONS (Child): STATEMENT:

The product shall support an agreed load and charger envelope.

ACCEPTANCE:

Electrical load profile and charger profile approved with voltage/current/pulse ranges.

METHOD:

Review

VMODEL_LEVEL:

Validation

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-005

EXECUTION:

Not Run

STK-003
3. STK-003 - Stakeholder UID: STK-003 STATUS: Draft DOMAIN: Stakeholder RELATIONS (Child): STATEMENT:

The product shall prevent hazardous electrical and thermal operating states.

ACCEPTANCE:

Hazard review identifies controls and verification for each unacceptable risk.

METHOD:

Review

VMODEL_LEVEL:

Validation

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

STK-004
4. STK-004 - Stakeholder UID: STK-004 STATUS: Draft DOMAIN: Stakeholder RELATIONS (Child): STATEMENT:

The engineering platform shall allow remote access to released engineering designs.

ACCEPTANCE:

Authorized browser can retrieve released CAD view, requirements, BOM, and reports.

METHOD:

Demo

VMODEL_LEVEL:

Validation

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • CAD-006
    73. CAD-006 - CAD UID: CAD-006 STATUS: Draft DOMAIN: CAD PARENT: STK-004 RELATIONS (Parent): STATEMENT:

    The build pipeline shall publish a browser-inspectable 3D derivative.

    ACCEPTANCE:

    GLB/glTF derivative opens in target browsers with part IDs and units intact.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • SIM-009
    84. SIM-009 - Simulation UID: SIM-009 STATUS: Draft DOMAIN: Simulation PARENT: STK-004 RELATIONS (Parent): STATEMENT:

    Interactive simulation shall return a useful lightweight response within the target UI budget.

    ACCEPTANCE:

    95th percentile local scenario calculation <2 seconds on target test workstation.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • PLT-001
    86. PLT-001 - Platform UID: PLT-001 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

    Authorized users shall access released projects through modern browsers.

    ACCEPTANCE:

    Desktop and mobile browser acceptance matrix passes.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • PLT-002
    87. PLT-002 - Platform UID: PLT-002 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

    Project access shall require authenticated identity and role authorization.

    ACCEPTANCE:

    Negative tests deny unauthenticated and cross-project access.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-020

    EXECUTION:

    Not Run

  • PLT-003
    88. PLT-003 - Platform UID: PLT-003 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

    Large CAD and simulation artifacts shall be stored in Google Cloud Storage.

    ACCEPTANCE:

    Artifact upload/download integrity hash matches and metadata indexed.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • PLT-005
    90. PLT-005 - Platform UID: PLT-005 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

    The UI shall display read-only released CAD model derivatives.

    ACCEPTANCE:

    Released revision loads and independent user cannot mutate master CAD.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • PLT-007
    92. PLT-007 - Platform UID: PLT-007 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

    Long simulation jobs shall execute outside synchronous web requests.

    ACCEPTANCE:

    Job survives browser disconnect; status and result remain retrievable.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-021

    EXECUTION:

    Not Run

  • PLT-008
    93. PLT-008 - Platform UID: PLT-008 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

    Cloud storage objects shall be recoverable under the approved backup policy.

    ACCEPTANCE:

    Documented restore drill recovers deliberately removed test dataset.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-022

    HAZARD_IDS:

    HZ-015

    EXECUTION:

    Not Run

  • PLT-009
    94. PLT-009 - Platform UID: PLT-009 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

    Remote application secrets shall not be embedded in downloaded browser assets.

    ACCEPTANCE:

    Security review and secret scanning identify no exposed credentials.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • PLT-012
    97. PLT-012 - Platform UID: PLT-012 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

    The platform shall refuse hazardous remote physical-bench actuation without local enable.

    ACCEPTANCE:

    Authorization negative test and physical local interlock demonstration pass.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-023

    HAZARD_IDS:

    HZ-013

    EXECUTION:

    Not Run

  • PLT-014
    99. PLT-014 - Platform UID: PLT-014 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

    Users shall see run state, errors, and diagnostic references for failed jobs.

    ACCEPTANCE:

    Forced solver failure yields log link, failure code, and no false 'passed' state.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

STK-005
5. STK-005 - Stakeholder UID: STK-005 STATUS: Draft DOMAIN: Stakeholder RELATIONS (Child): STATEMENT:

The platform shall trace design decisions to requirements and verification evidence.

ACCEPTANCE:

Sample 10 requirements traced bidirectionally through implementation and test reports.

METHOD:

Inspection

VMODEL_LEVEL:

Validation

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • SYS-010
    20. SYS-010 - System UID: SYS-010 STATUS: Draft DOMAIN: System PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Every completed system test shall identify the tested hardware and firmware revisions.

    ACCEPTANCE:

    Test artifacts contain immutable HW rev, FW hash, instrument calibration, date.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    System

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • FW-010
    48. FW-010 - Firmware UID: FW-010 STATUS: Draft DOMAIN: Firmware PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Every firmware release shall retain build provenance and checksum.

    ACCEPTANCE:

    Rebuild from pinned inputs reproduces version metadata and artifact hash policy.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Software

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • CAD-001
    68. CAD-001 - CAD UID: CAD-001 STATUS: Draft DOMAIN: CAD PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    The master model shall generate the declared pack geometry from controlled parameters.

    ACCEPTANCE:

    Regenerate 4S nominal variant without manual topology repair.

    METHOD:

    Demo

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-015

    EXECUTION:

    Not Run

  • CAD-007
    74. CAD-007 - CAD UID: CAD-007 STATUS: Draft DOMAIN: CAD PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    CAD outputs shall identify generator version and input parameter revision.

    ACCEPTANCE:

    Manifest links source file, hash, parameter set and derived file hash.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • SIM-001
    76. SIM-001 - Simulation UID: SIM-001 STATUS: Draft DOMAIN: Simulation PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    The digital twin shall expose a 4-cell electrical equivalent-circuit model.

    ACCEPTANCE:

    Model responds deterministically to frozen input scenario with baseline output.

    METHOD:

    Test

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • SIM-002
    77. SIM-002 - Simulation UID: SIM-002 STATUS: Draft DOMAIN: Simulation PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Each model run shall record parameter set, solver version and boundary conditions.

    ACCEPTANCE:

    100% sampled runs reproduce metadata manifest and result hashes.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-011

    EXECUTION:

    Not Run

  • SIM-003
    78. SIM-003 - Simulation UID: SIM-003 STATUS: Draft DOMAIN: Simulation PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    The simulator shall distinguish model predictions from measured test data.

    ACCEPTANCE:

    UI and exported report mark data origin at sample and series level.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • SIM-004
    79. SIM-004 - Simulation UID: SIM-004 STATUS: Draft DOMAIN: Simulation PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    The pack model shall report voltage, current, SOC, power and accumulated energy.

    ACCEPTANCE:

    Numerical conservation/reference checks and display unit tests pass.

    METHOD:

    Test

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-018

    EXECUTION:

    Not Run

  • SIM-005
    80. SIM-005 - Simulation UID: SIM-005 STATUS: Draft DOMAIN: Simulation PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    The pack model shall evaluate per-cell imbalance.

    ACCEPTANCE:

    Unbalanced cell synthetic case generates distinct cell states and alerts.

    METHOD:

    Test

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • SIM-010
    85. SIM-010 - Simulation UID: SIM-010 STATUS: Draft DOMAIN: Simulation PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Invalid model parameters shall be rejected before execution.

    ACCEPTANCE:

    Schema/physics guards reject negative resistance, zero mass, bad series count.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-019

    EXECUTION:

    Not Run

  • PLT-004
    89. PLT-004 - Platform UID: PLT-004 STATUS: Draft DOMAIN: Platform PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Requirement documents shall be managed as Git-versioned text sources.

    ACCEPTANCE:

    A change is traceable to commit, author, diff and review decision.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • PLT-006
    91. PLT-006 - Platform UID: PLT-006 STATUS: Draft DOMAIN: Platform PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Each simulation result shall reference immutable input and executable versions.

    ACCEPTANCE:

    Run manifest contains source commit, params checksum, solver version.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • PLT-010
    95. PLT-010 - Platform UID: PLT-010 STATUS: Draft DOMAIN: Platform PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    The system shall maintain immutable release manifests.

    ACCEPTANCE:

    Release includes refs/hashes for requirements, PCB, CAD, FW, BOM, test evidence.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-024

    HAZARD_IDS:

    HZ-015

    EXECUTION:

    Not Run

  • PLT-011
    96. PLT-011 - Platform UID: PLT-011 STATUS: Draft DOMAIN: Platform PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    The UI shall link each failed test to its governing requirement.

    ACCEPTANCE:

    Select failed test and navigate to matching requirement ID and commit.

    METHOD:

    Demo

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • PLT-013
    98. PLT-013 - Platform UID: PLT-013 STATUS: Draft DOMAIN: Platform PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    The platform shall preserve source measurements separately from derived simulation results.

    ACCEPTANCE:

    Original datasets content-addressed; transformations separately versioned.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • VER-001
    100. VER-001 - Verification UID: VER-001 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Every approved engineering requirement shall have a verification method and acceptance criterion.

    ACCEPTANCE:

    No approved requirements have blank method, criterion, or verification ID.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • VER-002
    101. VER-002 - Verification UID: VER-002 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Safety-critical requirements shall have a hazard link and review approval.

    ACCEPTANCE:

    100% safety-tagged requirements linked to at least one risk or safety rationale.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • VER-003
    102. VER-003 - Verification UID: VER-003 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Test cases shall identify setup, stimuli, expected result, actual result and artifacts.

    ACCEPTANCE:

    Sample tests contain all fields and independent rerun possible.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • VER-004
    103. VER-004 - Verification UID: VER-004 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Verification results shall distinguish Passed, Failed, Blocked and Not Run.

    ACCEPTANCE:

    Report schema validation rejects ambiguous status labels.

    METHOD:

    Test

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • VER-005
    104. VER-005 - Verification UID: VER-005 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    The system shall prohibit release on unresolved critical verification failures.

    ACCEPTANCE:

    Synthetic critical failure blocks release gate automatically.

    METHOD:

    Test

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-025

    EXECUTION:

    Not Run

  • VER-006
    105. VER-006 - Verification UID: VER-006 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Test equipment shall be linked to calibration status and uncertainty.

    ACCEPTANCE:

    Each measurement-based test has instrument ID, calibration date, uncertainty.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • VER-007
    106. VER-007 - Verification UID: VER-007 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Requirement changes after baseline shall trigger impact analysis.

    ACCEPTANCE:

    Diff lists affected architecture elements, CAD, PCB, FW and test IDs.

    METHOD:

    Demo

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • VER-008
    107. VER-008 - Verification UID: VER-008 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    System validation shall be distinguished from specification verification.

    ACCEPTANCE:

    V&V plan provides separate user-need acceptance and compliance evidence.

    METHOD:

    Review

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • VER-009
    108. VER-009 - Verification UID: VER-009 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Fault injection shall never energize an unguarded hazardous battery bench remotely.

    ACCEPTANCE:

    Interlock validation rejects remote command in unsafe configuration.

    METHOD:

    Test

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-013

    EXECUTION:

    Not Run

  • VER-010
    109. VER-010 - Verification UID: VER-010 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Regression suites shall run on every controlled software change.

    ACCEPTANCE:

    CI report records pass/fail, commit and test count for each merge.

    METHOD:

    Test

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • MFG-003
    119. MFG-003 - Manufacturing UID: MFG-003 STATUS: Draft DOMAIN: Manufacturing PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Each assembled pack shall carry serial and test result identity.

    ACCEPTANCE:

    Physical label resolves to build record, lot, FW and test data.

    METHOD:

    Test

    VMODEL_LEVEL:

    System

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-027

    EXECUTION:

    Not Run

  • MFG-006
    122. MFG-006 - Manufacturing UID: MFG-006 STATUS: Draft DOMAIN: Manufacturing PARENT: STK-005 RELATIONS (Parent): STATEMENT:

    Firmware programming and configuration shall be logged during end-of-line test.

    ACCEPTANCE:

    EOL record captures image hash, settings CRC and measured calibration data.

    METHOD:

    Test

    VMODEL_LEVEL:

    System

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

STK-006
6. STK-006 - Stakeholder UID: STK-006 STATUS: Draft DOMAIN: Stakeholder RELATIONS (Child): STATEMENT:

The project shall maintain a costed production BOM and approved alternatives.

ACCEPTANCE:

100% of released purchasable parts have source, quantity, cost and lifecycle status.

METHOD:

Inspection

VMODEL_LEVEL:

Validation

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • CAD-005
    72. CAD-005 - CAD UID: CAD-005 STATUS: Draft DOMAIN: CAD PARENT: STK-006 RELATIONS (Parent): STATEMENT:

    CAD part quantities shall be reconciled with the engineering BOM.

    ACCEPTANCE:

    All released CAD component IDs map to counted BOM positions.

    METHOD:

    Test

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-017

    EXECUTION:

    Not Run

  • BOM-001
    110. BOM-001 - BOM UID: BOM-001 STATUS: Draft DOMAIN: BOM PARENT: STK-006 RELATIONS (Parent): STATEMENT:

    Every approved purchasable part shall have a unique ID and revision.

    ACCEPTANCE:

    100% released parts have part numbers, approved footprint or spec and revision.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • BOM-002
    111. BOM-002 - BOM UID: BOM-002 STATUS: Draft DOMAIN: BOM PARENT: STK-006 RELATIONS (Parent): STATEMENT:

    The BOM shall separate cell, BMS, enclosure, harness and assembly cost.

    ACCEPTANCE:

    Cost rollup correctly sums subassembly and unit totals.

    METHOD:

    Test

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • BOM-003
    112. BOM-003 - BOM UID: BOM-003 STATUS: Draft DOMAIN: BOM PARENT: STK-006 RELATIONS (Parent): STATEMENT:

    Unit cost shall be calculated at prototype, 100 and 10000-unit quantities.

    ACCEPTANCE:

    Cost rollup produces price breaks with quote dates and currency.

    METHOD:

    Test

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-026

    EXECUTION:

    Not Run

  • BOM-004
    113. BOM-004 - BOM UID: BOM-004 STATUS: Draft DOMAIN: BOM PARENT: STK-006 RELATIONS (Parent): STATEMENT:

    Approved alternates shall preserve form-fit-function and qualification evidence.

    ACCEPTANCE:

    Replacement cannot be marked approved without referenced validation.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • BOM-005
    114. BOM-005 - BOM UID: BOM-005 STATUS: Draft DOMAIN: BOM PARENT: STK-006 RELATIONS (Parent): STATEMENT:

    The platform shall flag obsolete or single-source critical parts.

    ACCEPTANCE:

    Artificial supplier change triggers lifecycle risk flag.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • BOM-006
    115. BOM-006 - BOM UID: BOM-006 STATUS: Draft DOMAIN: BOM PARENT: STK-006 RELATIONS (Parent): STATEMENT:

    The system shall calculate estimated landed cost using separated assumptions.

    ACCEPTANCE:

    Formula validation covers price, scrap, assembly, freight and test yield.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • BOM-007
    116. BOM-007 - BOM UID: BOM-007 STATUS: Draft DOMAIN: BOM PARENT: STK-006 RELATIONS (Parent): STATEMENT:

    Any BOM cost comparison shall identify assumptions and quote validity.

    ACCEPTANCE:

    100% review samples show quote date and currency normalization.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • MFG-001
    117. MFG-001 - Manufacturing UID: MFG-001 STATUS: Draft DOMAIN: Manufacturing PARENT: STK-006 RELATIONS (Parent): STATEMENT:

    The pack shall have a defined assembly process with controlled order of operations.

    ACCEPTANCE:

    Approved work instructions identify each critical step and hazard.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • MFG-004
    120. MFG-004 - Manufacturing UID: MFG-004 STATUS: Draft DOMAIN: Manufacturing PARENT: STK-006 RELATIONS (Parent): STATEMENT:

    The project shall calculate yield-adjusted production BOM cost.

    ACCEPTANCE:

    Production estimate formula tests pass for multiple scrap/yield inputs.

    METHOD:

    Test

    VMODEL_LEVEL:

    Process

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

STK-007
7. STK-007 - Stakeholder UID: STK-007 STATUS: Draft DOMAIN: Stakeholder RELATIONS (Child): STATEMENT:

The product family shall support 24 V, 48 V and 72 V-class variants through controlled reuse.

ACCEPTANCE:

Family architecture defines reusable and variant-specific assets with no safety assumptions inherited implicitly.

METHOD:

Review

VMODEL_LEVEL:

Validation

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • CAD-002
    69. CAD-002 - CAD UID: CAD-002 STATUS: Draft DOMAIN: CAD PARENT: STK-007 RELATIONS (Parent): STATEMENT:

    The CAD generator shall support independent series count and cell dimensions within permitted families.

    ACCEPTANCE:

    Parameterized 4S/8S/16S geometries generated; invalid combinations rejected.

    METHOD:

    Test

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-016

    EXECUTION:

    Not Run

  • SCL-001
    123. SCL-001 - Scale-up UID: SCL-001 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

    The family architecture shall separate hardware-dependent protection from portable firmware logic.

    ACCEPTANCE:

    Design review identifies abstraction interfaces and variant-specific drivers.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Architecture

    RELEASE:

    V2+

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • SCL-002
    124. SCL-002 - Scale-up UID: SCL-002 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

    The platform shall reject designs where maximum pack voltage exceeds rated components.

    ACCEPTANCE:

    Static rule uses cell upper limit * series count against rated design envelope.

    METHOD:

    Test

    VMODEL_LEVEL:

    Platform

    RELEASE:

    V2+

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-014

    EXECUTION:

    Not Run

  • SCL-003
    125. SCL-003 - Scale-up UID: SCL-003 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

    The 8S variant shall receive its own sensing and power protection review.

    ACCEPTANCE:

    8S architecture sign-off includes sensor, FET, charger, thermal and fuse design.

    METHOD:

    Review

    VMODEL_LEVEL:

    Architecture

    RELEASE:

    V2+

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • SCL-004
    126. SCL-004 - Scale-up UID: SCL-004 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

    The 16S variant shall receive separate voltage/clearance and protection validation.

    ACCEPTANCE:

    16S revision has independent electrical and mechanical verification plan.

    METHOD:

    Review

    VMODEL_LEVEL:

    Architecture

    RELEASE:

    V3+

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • SCL-005
    127. SCL-005 - Scale-up UID: SCL-005 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

    The 72 V-class variant shall define nominal and absolute maximum voltage explicitly.

    ACCEPTANCE:

    System datasheet declares chemistry, series count and maximum charged voltage.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Architecture

    RELEASE:

    V4+

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-014

    EXECUTION:

    Not Run

  • SCL-006
    128. SCL-006 - Scale-up UID: SCL-006 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

    Higher-voltage variants shall be assessed for isolation and precharge requirements.

    ACCEPTANCE:

    Hazard/architecture review documents whether isolation and precharge are needed.

    METHOD:

    Analysis

    VMODEL_LEVEL:

    Architecture

    RELEASE:

    V4+

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • SCL-007
    129. SCL-007 - Scale-up UID: SCL-007 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

    Variants shall reuse requirement/test templates only after applicability review.

    ACCEPTANCE:

    Each inherited requirement lists applicable variants and any revised criterion.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Process

    RELEASE:

    V2+

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • SCL-008
    130. SCL-008 - Scale-up UID: SCL-008 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

    Series-connected modules shall be validated as one coordinated pack protection system.

    ACCEPTANCE:

    System fault model reviews worst-case module trip, imbalance, and unintended reclose.

    METHOD:

    Analysis

    VMODEL_LEVEL:

    System

    RELEASE:

    V4+

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

STK-008
8. STK-008 - Stakeholder UID: STK-008 STATUS: Draft DOMAIN: Stakeholder RELATIONS (Child): STATEMENT:

The product shall be serviceable using documented diagnostics and replaceable assemblies.

ACCEPTANCE:

Documented diagnostic workflow identifies each specified field-replaceable assembly.

METHOD:

Demo

VMODEL_LEVEL:

Validation

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • MEC-007
    57. MEC-007 - Mechanical UID: MEC-007 STATUS: Draft DOMAIN: Mechanical PARENT: STK-008 RELATIONS (Parent): STATEMENT:

    Serviceable components shall be accessible without disturbing cell terminals unintentionally.

    ACCEPTANCE:

    Service procedure dry-run demonstrates defined replacement and isolation sequence.

    METHOD:

    Demo

    VMODEL_LEVEL:

    System

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

STK-009
9. STK-009 - Stakeholder UID: STK-009 STATUS: Draft DOMAIN: Stakeholder RELATIONS (Child): STATEMENT:

The product shall meet the environmental and mechanical needs of its intended use.

ACCEPTANCE:

Environmental profile and corresponding qualification plan approved.

METHOD:

Review

VMODEL_LEVEL:

Validation

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

STK-010
10. STK-010 - Stakeholder UID: STK-010 STATUS: Draft DOMAIN: Stakeholder STATEMENT:

The project shall support independent review and controlled engineering releases.

ACCEPTANCE:

Each released baseline carries approver, version, date and evidence manifest.

METHOD:

Inspection

VMODEL_LEVEL:

Validation

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • STK-001
    1. STK-001 - Stakeholder UID: STK-001 STATUS: Draft DOMAIN: Stakeholder RELATIONS (Child): STATEMENT:

    The product shall provide a replaceable 12.8 V nominal rechargeable energy source.

    ACCEPTANCE:

    4S1P LFP reference architecture reviewed against intended load.

    METHOD:

    Review

    VMODEL_LEVEL:

    Validation

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

SYS-001
11. SYS-001 - System UID: SYS-001 STATUS: Draft DOMAIN: System PARENT: STK-001 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

The V1 pack shall contain four LFP cells connected in series.

ACCEPTANCE:

As-built cell count=4 and measured polarity/topology matches schematic.

METHOD:

Inspection

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-001

EXECUTION:

Not Run

  • CEL-001
    21. CEL-001 - Cell UID: CEL-001 STATUS: Draft DOMAIN: Cell PARENT: SYS-001 RELATIONS (Parent): STATEMENT:

    Each cell shall be traceable to an approved manufacturer and part number.

    ACCEPTANCE:

    Serial/lot, source datasheet and supplier documented for every prototype cell.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Component

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-003

    EXECUTION:

    Not Run

  • CEL-002
    22. CEL-002 - Cell UID: CEL-002 STATUS: Draft DOMAIN: Cell PARENT: SYS-001 RELATIONS (Parent): STATEMENT:

    The selected cell shall provide at least 20 Ah nominal capacity under its specified conditions.

    ACCEPTANCE:

    Manufacturer spec confirmed and capacity acceptance test method approved.

    METHOD:

    Test

    VMODEL_LEVEL:

    Component

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • CEL-005
    25. CEL-005 - Cell UID: CEL-005 STATUS: Draft DOMAIN: Cell PARENT: SYS-001 RELATIONS (Parent): STATEMENT:

    Cell model parameters shall identify manufacturer, chemistry, revision and test conditions.

    ACCEPTANCE:

    Model dataset contains provenance and temperature/current metadata.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Component

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • CEL-006
    26. CEL-006 - Cell UID: CEL-006 STATUS: Draft DOMAIN: Cell PARENT: SYS-001 RELATIONS (Parent): STATEMENT:

    Cell selection shall include a defined matching and incoming quality procedure.

    ACCEPTANCE:

    Incoming inspection evaluates approved capacity, resistance and visual criteria.

    METHOD:

    Test

    VMODEL_LEVEL:

    Component

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • MEC-001
    51. MEC-001 - Mechanical UID: MEC-001 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-001 RELATIONS (Parent): STATEMENT:

    The pack shall secure four cells in the declared CAD orientation.

    ACCEPTANCE:

    Assembly fit-check agrees with released drawing and stack tolerances.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • CAD-003
    70. CAD-003 - CAD UID: CAD-003 STATUS: Draft DOMAIN: CAD PARENT: SYS-001 RELATIONS (Parent): STATEMENT:

    Each CAD cell shall reference an approved part geometry and tolerance set.

    ACCEPTANCE:

    Part ID and dimensions match supplier drawing and imported material record.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • STK-001
    1. STK-001 - Stakeholder UID: STK-001 STATUS: Draft DOMAIN: Stakeholder RELATIONS (Child): STATEMENT:

    The product shall provide a replaceable 12.8 V nominal rechargeable energy source.

    ACCEPTANCE:

    4S1P LFP reference architecture reviewed against intended load.

    METHOD:

    Review

    VMODEL_LEVEL:

    Validation

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

SYS-002
12. SYS-002 - System UID: SYS-002 STATUS: Draft DOMAIN: System PARENT: STK-001 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

The V1 reference energy shall be 256 Wh nominal.

ACCEPTANCE:

4 × 3.2 V × 20 Ah = 256 Wh in approved reference model.

METHOD:

Analysis

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • ELE-010
    37. ELE-010 - Electrical UID: ELE-010 STATUS: Draft DOMAIN: Electrical PARENT: SYS-002 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    Battery positive and negative polarity shall be unambiguous at external terminals.

    ACCEPTANCE:

    Drawing, labels and as-built inspection agree.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-004

    EXECUTION:

    Not Run

SYS-003
13. SYS-003 - System UID: SYS-003 STATUS: Draft DOMAIN: System PARENT: STK-002 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

The V1 pack shall support 20 A continuous discharge at the specified ambient and SOC.

ACCEPTANCE:

Validated steady-state load profile maintained without exceeding approved electrical/thermal limits.

METHOD:

Test

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • THM-001
    60. THM-001 - Thermal UID: THM-001 STATUS: Draft DOMAIN: Thermal PARENT: SYS-003 RELATIONS (Parent): STATEMENT:

    The thermal model shall represent resistive losses in cells and power path.

    ACCEPTANCE:

    Energy balance and I²R term unit tests pass.

    METHOD:

    Analysis

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • THM-002
    61. THM-002 - Thermal UID: THM-002 STATUS: Draft DOMAIN: Thermal PARENT: SYS-003 RELATIONS (Parent): STATEMENT:

    The thermal model shall represent ambient convection and thermal contact paths.

    ACCEPTANCE:

    Parameters and boundary conditions documented with units and sources.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • THM-003
    62. THM-003 - Thermal UID: THM-003 STATUS: Draft DOMAIN: Thermal PARENT: SYS-003 RELATIONS (Parent): STATEMENT:

    Thermal response shall be estimated for nominal load and agreed duty cycle.

    ACCEPTANCE:

    Transient prediction and assumptions exported for each approved scenario.

    METHOD:

    Analysis

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • THM-004
    63. THM-004 - Thermal UID: THM-004 STATUS: Draft DOMAIN: Thermal PARENT: SYS-003 RELATIONS (Parent): STATEMENT:

    The hottest measured cell location shall be included in a validation plan.

    ACCEPTANCE:

    Thermocouple map identifies expected hotspot and representative measurements.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    System

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • THM-005
    64. THM-005 - Thermal UID: THM-005 STATUS: Draft DOMAIN: Thermal PARENT: SYS-003 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    Thermal simulation accuracy shall be assessed against measured pack temperatures.

    ACCEPTANCE:

    Correlation error and uncertainty reported across >= 3 agreed load profiles.

    METHOD:

    Test

    VMODEL_LEVEL:

    System

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-012

    HAZARD_IDS:

    HZ-011

    EXECUTION:

    Not Run

SYS-004
14. SYS-004 - System UID: SYS-004 STATUS: Draft DOMAIN: System PARENT: STK-002 RELATIONS (Parent): STATEMENT:

The V1 pack shall support 10 A charging where the cell supplier permits.

ACCEPTANCE:

Charge test at 10 A passes supplier temperature, voltage, and current limits.

METHOD:

Test

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-005

EXECUTION:

Not Run

SYS-005
15. SYS-005 - System UID: SYS-005 STATUS: Draft DOMAIN: System PARENT: STK-003 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

The pack shall interrupt charge/discharge according to the approved protection state table.

ACCEPTANCE:

Each listed fault produces expected output state and recorded event.

METHOD:

Test

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-004, TR-005

HAZARD_IDS:

HZ-001

EXECUTION:

Not Run

  • ELE-001
    28. ELE-001 - Electrical UID: ELE-001 STATUS: Draft DOMAIN: Electrical PARENT: SYS-005 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    The system shall measure every series-cell voltage independently.

    ACCEPTANCE:

    Four channels mapped and calibrated against reference instrument.

    METHOD:

    Test

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-002

    HAZARD_IDS:

    HZ-001

    EXECUTION:

    Not Run

  • ELE-002
    29. ELE-002 - Electrical UID: ELE-002 STATUS: Draft DOMAIN: Electrical PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

    Cell voltage measurement error shall remain within the approved error budget.

    ACCEPTANCE:

    Measured worst-case absolute error <= frozen sensing accuracy budget.

    METHOD:

    Test

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-003

    EXECUTION:

    Not Run

  • ELE-003
    30. ELE-003 - Electrical UID: ELE-003 STATUS: Draft DOMAIN: Electrical PARENT: SYS-005 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    Pack current shall be measured in both charge and discharge directions.

    ACCEPTANCE:

    Calibrated positive and negative currents within approved sensing error budget.

    METHOD:

    Test

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • ELE-004
    31. ELE-004 - Electrical UID: ELE-004 STATUS: Draft DOMAIN: Electrical PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

    The system shall detect an open cell-sense lead or enter a defined safe state.

    ACCEPTANCE:

    Each applicable sense-lead disconnect produces mapped fault/safe state.

    METHOD:

    Test

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-006

    HAZARD_IDS:

    HZ-008

    EXECUTION:

    Not Run

  • ELE-009
    36. ELE-009 - Electrical UID: ELE-009 STATUS: Draft DOMAIN: Electrical PARENT: SYS-005 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    The BMS shall support a documented balancing strategy.

    ACCEPTANCE:

    Balancing activation, inhibition, current and thermal budget tested.

    METHOD:

    Test

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-011

    EXECUTION:

    Not Run

  • ELE-011
    38. ELE-011 - Electrical UID: ELE-011 STATUS: Draft DOMAIN: Electrical PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

    BMS power consumption shall remain within an approved storage and standby budget.

    ACCEPTANCE:

    Measured operating/sleep current versus frozen current budget.

    METHOD:

    Test

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • FW-001
    39. FW-001 - Firmware UID: FW-001 STATUS: Draft DOMAIN: Firmware PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

    The firmware shall implement explicit INIT, IDLE, CHARGE, DISCHARGE, FAULT and SLEEP states.

    ACCEPTANCE:

    All allowed and forbidden transitions covered by automated state table tests.

    METHOD:

    Test

    VMODEL_LEVEL:

    Software

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-008

    EXECUTION:

    Not Run

  • FW-002
    40. FW-002 - Firmware UID: FW-002 STATUS: Draft DOMAIN: Firmware PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

    The firmware shall not override autonomous hardware protection to enable unsafe current.

    ACCEPTANCE:

    Fault injection demonstrates external commands cannot bypass hardware protection.

    METHOD:

    Test

    VMODEL_LEVEL:

    Software

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-009

    HAZARD_IDS:

    HZ-012

    EXECUTION:

    Not Run

  • FW-007
    45. FW-007 - Firmware UID: FW-007 STATUS: Draft DOMAIN: Firmware PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

    The firmware shall retain a fault cause across a reset when specified by fault policy.

    ACCEPTANCE:

    Reset/power-cycle test demonstrates event persists until authorized clearing.

    METHOD:

    Test

    VMODEL_LEVEL:

    Software

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • FW-008
    46. FW-008 - Firmware UID: FW-008 STATUS: Draft DOMAIN: Firmware PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

    The firmware shall detect stalled critical tasks through watchdog supervision.

    ACCEPTANCE:

    Injected task stall leads to defined fail-safe outcome.

    METHOD:

    Test

    VMODEL_LEVEL:

    Software

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-012

    EXECUTION:

    Not Run

  • FW-011
    49. FW-011 - Firmware UID: FW-011 STATUS: Draft DOMAIN: Firmware PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

    The firmware shall detect stale or invalid temperature data.

    ACCEPTANCE:

    Loss/stuck-sensor simulated; safe-state policy passes all defined cases.

    METHOD:

    Test

    VMODEL_LEVEL:

    Software

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-006

    EXECUTION:

    Not Run

  • THM-006
    65. THM-006 - Thermal UID: THM-006 STATUS: Draft DOMAIN: Thermal PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

    The BMS shall block charging outside the permitted cell thermal range.

    ACCEPTANCE:

    Boundary fault test shows expected cutoff and recovery behavior.

    METHOD:

    Test

    VMODEL_LEVEL:

    System

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-006

    EXECUTION:

    Not Run

  • THM-007
    66. THM-007 - Thermal UID: THM-007 STATUS: Draft DOMAIN: Thermal PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

    The BMS shall block discharge outside the permitted cell thermal range.

    ACCEPTANCE:

    Boundary fault test shows expected cutoff and recovery behavior.

    METHOD:

    Test

    VMODEL_LEVEL:

    System

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

SYS-006
16. SYS-006 - System UID: SYS-006 STATUS: Draft DOMAIN: System PARENT: STK-003 RELATIONS (Parent): STATEMENT:

Pack overcurrent/short-circuit protection shall not depend on a cloud connection.

ACCEPTANCE:

Connectivity removed; hardware protection remains functional in supervised bench test.

METHOD:

Test

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-007

HAZARD_IDS:

HZ-002

EXECUTION:

Not Run

SYS-007
17. SYS-007 - System UID: SYS-007 STATUS: Draft DOMAIN: System PARENT: STK-003 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

The pack shall incorporate a coordinated fuse and electronic protection concept.

ACCEPTANCE:

Safety review validates fuse ratings, FET SOA, fault energy, wiring, and disconnection behavior.

METHOD:

Analysis

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-002, HZ-007

EXECUTION:

Not Run

  • ELE-005
    32. ELE-005 - Electrical UID: ELE-005 STATUS: Draft DOMAIN: Electrical PARENT: SYS-007 RELATIONS (Parent): STATEMENT:

    Protection switches shall withstand approved continuous, pulse and fault operating cases.

    ACCEPTANCE:

    Thermal, SOA and transient calculations signed off; representative tests pass.

    METHOD:

    Analysis

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-007

    EXECUTION:

    Not Run

  • ELE-006
    33. ELE-006 - Electrical UID: ELE-006 STATUS: Draft DOMAIN: Electrical PARENT: SYS-007 RELATIONS (Parent): STATEMENT:

    The battery shall have a fuse coordinated with conductor and fault energy limits.

    ACCEPTANCE:

    Fuse I²t, expected prospective short current and conductor limits reviewed.

    METHOD:

    Analysis

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • MEC-003
    53. MEC-003 - Mechanical UID: MEC-003 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-007 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    Electrical insulation shall prevent accidental busbar-enclosure contact in all specified tolerances.

    ACCEPTANCE:

    CAD clearance check and physical inspection against frozen spacing standard.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-003

    EXECUTION:

    Not Run

  • MEC-006
    56. MEC-006 - Mechanical UID: MEC-006 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-007 RELATIONS (Parent): STATEMENT:

    Busbar fastening shall use controlled fastener and torque specifications.

    ACCEPTANCE:

    Assembly inspection documents torque procedure, washer and locking approach.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-014

    HAZARD_IDS:

    HZ-009

    EXECUTION:

    Not Run

  • MFG-002
    118. MFG-002 - Manufacturing UID: MFG-002 STATUS: Draft DOMAIN: Manufacturing PARENT: SYS-007 RELATIONS (Parent): STATEMENT:

    Pack terminal, fuse and busbar assembly shall have prescribed inspection checks.

    ACCEPTANCE:

    EOL checklist verifies polarity, continuity and fastener records.

    METHOD:

    Test

    VMODEL_LEVEL:

    System

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-004

    EXECUTION:

    Not Run

SYS-008
18. SYS-008 - System UID: SYS-008 STATUS: Draft DOMAIN: System PARENT: STK-002 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

The pack shall expose a defined service interface for diagnostics.

ACCEPTANCE:

All protocol commands pass interface conformance tests.

METHOD:

Test

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • ELE-007
    34. ELE-007 - Electrical UID: ELE-007 STATUS: Draft DOMAIN: Electrical PARENT: SYS-008 RELATIONS (Parent): STATEMENT:

    Diagnostic connector pinout shall be keyed and defined.

    ACCEPTANCE:

    ICD and physical inspection show no ambiguous voltage/polarity connections.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • FW-005
    43. FW-005 - Firmware UID: FW-005 STATUS: Draft DOMAIN: Firmware PARENT: SYS-008 RELATIONS (Parent): STATEMENT:

    The firmware shall expose versioned diagnostic telemetry.

    ACCEPTANCE:

    Protocol tests validate schema, units, timestamps and version negotiation.

    METHOD:

    Test

    VMODEL_LEVEL:

    Software

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • FW-009
    47. FW-009 - Firmware UID: FW-009 STATUS: Draft DOMAIN: Firmware PARENT: SYS-008 RELATIONS (Parent): STATEMENT:

    The firmware shall reject malformed or unauthorized configuration commands.

    ACCEPTANCE:

    Protocol negative and authorization tests reject invalid writes.

    METHOD:

    Test

    VMODEL_LEVEL:

    Software

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • FW-012
    50. FW-012 - Firmware UID: FW-012 STATUS: Draft DOMAIN: Firmware PARENT: SYS-008 RELATIONS (Parent): STATEMENT:

    The firmware shall support a controlled calibration data procedure.

    ACCEPTANCE:

    Calibration revision and CRC verified; corrupt configuration rejected.

    METHOD:

    Test

    VMODEL_LEVEL:

    Software

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • STK-009
    9. STK-009 - Stakeholder UID: STK-009 STATUS: Draft DOMAIN: Stakeholder RELATIONS (Child): STATEMENT:

    The product shall meet the environmental and mechanical needs of its intended use.

    ACCEPTANCE:

    Environmental profile and corresponding qualification plan approved.

    METHOD:

    Review

    VMODEL_LEVEL:

    Validation

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

SYS-009
19. SYS-009 - System UID: SYS-009 STATUS: Draft DOMAIN: System PARENT: STK-009 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

The pack shall comply with an approved system operating envelope.

ACCEPTANCE:

Operating envelope table approved and full boundary-condition test coverage assigned.

METHOD:

Review

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • CEL-003
    23. CEL-003 - Cell UID: CEL-003 STATUS: Draft DOMAIN: Cell PARENT: SYS-009 RELATIONS (Parent): STATEMENT:

    The design shall prevent cell operation outside supplier charge temperature limits.

    ACCEPTANCE:

    Boundary test inhibits charge as required by frozen cell specification.

    METHOD:

    Test

    VMODEL_LEVEL:

    Component

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • CEL-004
    24. CEL-004 - Cell UID: CEL-004 STATUS: Draft DOMAIN: Cell PARENT: SYS-009 RELATIONS (Parent): STATEMENT:

    The design shall prevent cell operation outside supplier discharge temperature limits.

    ACCEPTANCE:

    Boundary test inhibits discharge as required by frozen cell specification.

    METHOD:

    Test

    VMODEL_LEVEL:

    Component

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • CEL-007
    27. CEL-007 - Cell UID: CEL-007 STATUS: Draft DOMAIN: Cell PARENT: SYS-009 RELATIONS (Parent): STATEMENT:

    Cell compression and orientation shall conform to supplier mechanical limits.

    ACCEPTANCE:

    Approved fixture and compression specification reviewed against supplier data.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Component

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • ELE-008
    35. ELE-008 - Electrical UID: ELE-008 STATUS: Draft DOMAIN: Electrical PARENT: SYS-009 RELATIONS (Parent): STATEMENT:

    PCB creepage, clearance and trace geometry shall meet the approved design rules.

    ACCEPTANCE:

    Automated DRC zero blockers; independent safety spacing review passed.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • MEC-002
    52. MEC-002 - Mechanical UID: MEC-002 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-009 RELATIONS (Parent): STATEMENT:

    Cell restraints shall comply with the manufacturer compression limits.

    ACCEPTANCE:

    Worst-case tolerance and clamping force verified against supplier envelope.

    METHOD:

    Analysis

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • MEC-004
    54. MEC-004 - Mechanical UID: MEC-004 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-009 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    The enclosure shall withstand the approved static mounting loads.

    ACCEPTANCE:

    FEA and representative physical fixture test meet displacement/stress criteria.

    METHOD:

    Test

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-010

    EXECUTION:

    Not Run

  • MEC-005
    55. MEC-005 - Mechanical UID: MEC-005 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-009 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    The mounting design shall avoid unacceptable resonances in the operational vibration profile.

    ACCEPTANCE:

    Modal test correlated to model; resonant response compared to approved limits.

    METHOD:

    Test

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-013

    HAZARD_IDS:

    HZ-009, HZ-010

    EXECUTION:

    Not Run

  • MEC-008
    58. MEC-008 - Mechanical UID: MEC-008 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-009 RELATIONS (Parent): STATEMENT:

    Mechanical BOM mass shall match CAD estimate within the approved discrepancy limit.

    ACCEPTANCE:

    As-built pack mass reconciled to CAD/material mass budget.

    METHOD:

    Test

    VMODEL_LEVEL:

    System

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • MEC-009
    59. MEC-009 - Mechanical UID: MEC-009 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-009 RELATIONS (Parent): STATEMENT:

    Critical dimensions and tolerances shall be present in manufacturing drawings.

    ACCEPTANCE:

    Drawing review verifies dimensions, datum strategy, tolerances and revision labels.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

SYS-010
20. SYS-010 - System UID: SYS-010 STATUS: Draft DOMAIN: System PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Every completed system test shall identify the tested hardware and firmware revisions.

ACCEPTANCE:

Test artifacts contain immutable HW rev, FW hash, instrument calibration, date.

METHOD:

Inspection

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

CEL-001
21. CEL-001 - Cell UID: CEL-001 STATUS: Draft DOMAIN: Cell PARENT: SYS-001 RELATIONS (Parent): STATEMENT:

Each cell shall be traceable to an approved manufacturer and part number.

ACCEPTANCE:

Serial/lot, source datasheet and supplier documented for every prototype cell.

METHOD:

Inspection

VMODEL_LEVEL:

Component

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-003

EXECUTION:

Not Run

CEL-002
22. CEL-002 - Cell UID: CEL-002 STATUS: Draft DOMAIN: Cell PARENT: SYS-001 RELATIONS (Parent): STATEMENT:

The selected cell shall provide at least 20 Ah nominal capacity under its specified conditions.

ACCEPTANCE:

Manufacturer spec confirmed and capacity acceptance test method approved.

METHOD:

Test

VMODEL_LEVEL:

Component

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

CEL-003
23. CEL-003 - Cell UID: CEL-003 STATUS: Draft DOMAIN: Cell PARENT: SYS-009 RELATIONS (Parent): STATEMENT:

The design shall prevent cell operation outside supplier charge temperature limits.

ACCEPTANCE:

Boundary test inhibits charge as required by frozen cell specification.

METHOD:

Test

VMODEL_LEVEL:

Component

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

CEL-004
24. CEL-004 - Cell UID: CEL-004 STATUS: Draft DOMAIN: Cell PARENT: SYS-009 RELATIONS (Parent): STATEMENT:

The design shall prevent cell operation outside supplier discharge temperature limits.

ACCEPTANCE:

Boundary test inhibits discharge as required by frozen cell specification.

METHOD:

Test

VMODEL_LEVEL:

Component

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

CEL-005
25. CEL-005 - Cell UID: CEL-005 STATUS: Draft DOMAIN: Cell PARENT: SYS-001 RELATIONS (Parent): STATEMENT:

Cell model parameters shall identify manufacturer, chemistry, revision and test conditions.

ACCEPTANCE:

Model dataset contains provenance and temperature/current metadata.

METHOD:

Inspection

VMODEL_LEVEL:

Component

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

CEL-006
26. CEL-006 - Cell UID: CEL-006 STATUS: Draft DOMAIN: Cell PARENT: SYS-001 RELATIONS (Parent): STATEMENT:

Cell selection shall include a defined matching and incoming quality procedure.

ACCEPTANCE:

Incoming inspection evaluates approved capacity, resistance and visual criteria.

METHOD:

Test

VMODEL_LEVEL:

Component

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

CEL-007
27. CEL-007 - Cell UID: CEL-007 STATUS: Draft DOMAIN: Cell PARENT: SYS-009 RELATIONS (Parent): STATEMENT:

Cell compression and orientation shall conform to supplier mechanical limits.

ACCEPTANCE:

Approved fixture and compression specification reviewed against supplier data.

METHOD:

Inspection

VMODEL_LEVEL:

Component

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

ELE-001
28. ELE-001 - Electrical UID: ELE-001 STATUS: Draft DOMAIN: Electrical PARENT: SYS-005 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

The system shall measure every series-cell voltage independently.

ACCEPTANCE:

Four channels mapped and calibrated against reference instrument.

METHOD:

Test

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-002

HAZARD_IDS:

HZ-001

EXECUTION:

Not Run

  • FW-003
    41. FW-003 - Firmware UID: FW-003 STATUS: Draft DOMAIN: Firmware PARENT: ELE-001 RELATIONS (Parent): STATEMENT:

    The firmware shall acquire and validate per-cell voltage samples.

    ACCEPTANCE:

    Unit tests cover scaling, range checking, invalid data and stale samples.

    METHOD:

    Test

    VMODEL_LEVEL:

    Software

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

ELE-002
29. ELE-002 - Electrical UID: ELE-002 STATUS: Draft DOMAIN: Electrical PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

Cell voltage measurement error shall remain within the approved error budget.

ACCEPTANCE:

Measured worst-case absolute error <= frozen sensing accuracy budget.

METHOD:

Test

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-003

EXECUTION:

Not Run

ELE-003
30. ELE-003 - Electrical UID: ELE-003 STATUS: Draft DOMAIN: Electrical PARENT: SYS-005 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

Pack current shall be measured in both charge and discharge directions.

ACCEPTANCE:

Calibrated positive and negative currents within approved sensing error budget.

METHOD:

Test

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • FW-004
    42. FW-004 - Firmware UID: FW-004 STATUS: Draft DOMAIN: Firmware PARENT: ELE-003 RELATIONS (Parent): STATEMENT:

    The firmware shall maintain a signed coulomb-counting current integral.

    ACCEPTANCE:

    Synthetic charge/discharge traces reproduce expected integrated Ah within numerical tolerance.

    METHOD:

    Test

    VMODEL_LEVEL:

    Software

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-010

    EXECUTION:

    Not Run

ELE-004
31. ELE-004 - Electrical UID: ELE-004 STATUS: Draft DOMAIN: Electrical PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

The system shall detect an open cell-sense lead or enter a defined safe state.

ACCEPTANCE:

Each applicable sense-lead disconnect produces mapped fault/safe state.

METHOD:

Test

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-006

HAZARD_IDS:

HZ-008

EXECUTION:

Not Run

ELE-005
32. ELE-005 - Electrical UID: ELE-005 STATUS: Draft DOMAIN: Electrical PARENT: SYS-007 RELATIONS (Parent): STATEMENT:

Protection switches shall withstand approved continuous, pulse and fault operating cases.

ACCEPTANCE:

Thermal, SOA and transient calculations signed off; representative tests pass.

METHOD:

Analysis

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-007

EXECUTION:

Not Run

ELE-006
33. ELE-006 - Electrical UID: ELE-006 STATUS: Draft DOMAIN: Electrical PARENT: SYS-007 RELATIONS (Parent): STATEMENT:

The battery shall have a fuse coordinated with conductor and fault energy limits.

ACCEPTANCE:

Fuse I²t, expected prospective short current and conductor limits reviewed.

METHOD:

Analysis

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

ELE-007
34. ELE-007 - Electrical UID: ELE-007 STATUS: Draft DOMAIN: Electrical PARENT: SYS-008 RELATIONS (Parent): STATEMENT:

Diagnostic connector pinout shall be keyed and defined.

ACCEPTANCE:

ICD and physical inspection show no ambiguous voltage/polarity connections.

METHOD:

Inspection

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

ELE-008
35. ELE-008 - Electrical UID: ELE-008 STATUS: Draft DOMAIN: Electrical PARENT: SYS-009 RELATIONS (Parent): STATEMENT:

PCB creepage, clearance and trace geometry shall meet the approved design rules.

ACCEPTANCE:

Automated DRC zero blockers; independent safety spacing review passed.

METHOD:

Inspection

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

ELE-009
36. ELE-009 - Electrical UID: ELE-009 STATUS: Draft DOMAIN: Electrical PARENT: SYS-005 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

The BMS shall support a documented balancing strategy.

ACCEPTANCE:

Balancing activation, inhibition, current and thermal budget tested.

METHOD:

Test

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-011

EXECUTION:

Not Run

  • FW-006
    44. FW-006 - Firmware UID: FW-006 STATUS: Draft DOMAIN: Firmware PARENT: ELE-009 RELATIONS (Parent): STATEMENT:

    The firmware shall inhibit balancing under disallowed thermal/electrical states.

    ACCEPTANCE:

    State-based tests cover all balancing inhibit conditions.

    METHOD:

    Test

    VMODEL_LEVEL:

    Software

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • THM-008
    67. THM-008 - Thermal UID: THM-008 STATUS: Draft DOMAIN: Thermal PARENT: ELE-009 RELATIONS (Parent): STATEMENT:

    Cell balancing heat shall be represented in BMS thermal budget.

    ACCEPTANCE:

    Worst-case balancing condition analysed and design review approved.

    METHOD:

    Analysis

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

  • SYS-002
    12. SYS-002 - System UID: SYS-002 STATUS: Draft DOMAIN: System PARENT: STK-001 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    The V1 reference energy shall be 256 Wh nominal.

    ACCEPTANCE:

    4 × 3.2 V × 20 Ah = 256 Wh in approved reference model.

    METHOD:

    Analysis

    VMODEL_LEVEL:

    System

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

ELE-010
37. ELE-010 - Electrical UID: ELE-010 STATUS: Draft DOMAIN: Electrical PARENT: SYS-002 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

Battery positive and negative polarity shall be unambiguous at external terminals.

ACCEPTANCE:

Drawing, labels and as-built inspection agree.

METHOD:

Inspection

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-004

EXECUTION:

Not Run

  • CAD-004
    71. CAD-004 - CAD UID: CAD-004 STATUS: Draft DOMAIN: CAD PARENT: ELE-010 RELATIONS (Parent): STATEMENT:

    The CAD assembly shall include terminals, busbars, BMS board, restraints and enclosure.

    ACCEPTANCE:

    Released exploded assembly lists every defined subassembly.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

ELE-011
38. ELE-011 - Electrical UID: ELE-011 STATUS: Draft DOMAIN: Electrical PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

BMS power consumption shall remain within an approved storage and standby budget.

ACCEPTANCE:

Measured operating/sleep current versus frozen current budget.

METHOD:

Test

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

FW-001
39. FW-001 - Firmware UID: FW-001 STATUS: Draft DOMAIN: Firmware PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

The firmware shall implement explicit INIT, IDLE, CHARGE, DISCHARGE, FAULT and SLEEP states.

ACCEPTANCE:

All allowed and forbidden transitions covered by automated state table tests.

METHOD:

Test

VMODEL_LEVEL:

Software

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-008

EXECUTION:

Not Run

FW-002
40. FW-002 - Firmware UID: FW-002 STATUS: Draft DOMAIN: Firmware PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

The firmware shall not override autonomous hardware protection to enable unsafe current.

ACCEPTANCE:

Fault injection demonstrates external commands cannot bypass hardware protection.

METHOD:

Test

VMODEL_LEVEL:

Software

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-009

HAZARD_IDS:

HZ-012

EXECUTION:

Not Run

  • ELE-001
    28. ELE-001 - Electrical UID: ELE-001 STATUS: Draft DOMAIN: Electrical PARENT: SYS-005 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    The system shall measure every series-cell voltage independently.

    ACCEPTANCE:

    Four channels mapped and calibrated against reference instrument.

    METHOD:

    Test

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-002

    HAZARD_IDS:

    HZ-001

    EXECUTION:

    Not Run

FW-003
41. FW-003 - Firmware UID: FW-003 STATUS: Draft DOMAIN: Firmware PARENT: ELE-001 RELATIONS (Parent): STATEMENT:

The firmware shall acquire and validate per-cell voltage samples.

ACCEPTANCE:

Unit tests cover scaling, range checking, invalid data and stale samples.

METHOD:

Test

VMODEL_LEVEL:

Software

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • ELE-003
    30. ELE-003 - Electrical UID: ELE-003 STATUS: Draft DOMAIN: Electrical PARENT: SYS-005 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    Pack current shall be measured in both charge and discharge directions.

    ACCEPTANCE:

    Calibrated positive and negative currents within approved sensing error budget.

    METHOD:

    Test

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

FW-004
42. FW-004 - Firmware UID: FW-004 STATUS: Draft DOMAIN: Firmware PARENT: ELE-003 RELATIONS (Parent): STATEMENT:

The firmware shall maintain a signed coulomb-counting current integral.

ACCEPTANCE:

Synthetic charge/discharge traces reproduce expected integrated Ah within numerical tolerance.

METHOD:

Test

VMODEL_LEVEL:

Software

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-010

EXECUTION:

Not Run

FW-005
43. FW-005 - Firmware UID: FW-005 STATUS: Draft DOMAIN: Firmware PARENT: SYS-008 RELATIONS (Parent): STATEMENT:

The firmware shall expose versioned diagnostic telemetry.

ACCEPTANCE:

Protocol tests validate schema, units, timestamps and version negotiation.

METHOD:

Test

VMODEL_LEVEL:

Software

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

FW-006
44. FW-006 - Firmware UID: FW-006 STATUS: Draft DOMAIN: Firmware PARENT: ELE-009 RELATIONS (Parent): STATEMENT:

The firmware shall inhibit balancing under disallowed thermal/electrical states.

ACCEPTANCE:

State-based tests cover all balancing inhibit conditions.

METHOD:

Test

VMODEL_LEVEL:

Software

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

FW-007
45. FW-007 - Firmware UID: FW-007 STATUS: Draft DOMAIN: Firmware PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

The firmware shall retain a fault cause across a reset when specified by fault policy.

ACCEPTANCE:

Reset/power-cycle test demonstrates event persists until authorized clearing.

METHOD:

Test

VMODEL_LEVEL:

Software

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

FW-008
46. FW-008 - Firmware UID: FW-008 STATUS: Draft DOMAIN: Firmware PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

The firmware shall detect stalled critical tasks through watchdog supervision.

ACCEPTANCE:

Injected task stall leads to defined fail-safe outcome.

METHOD:

Test

VMODEL_LEVEL:

Software

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-012

EXECUTION:

Not Run

FW-009
47. FW-009 - Firmware UID: FW-009 STATUS: Draft DOMAIN: Firmware PARENT: SYS-008 RELATIONS (Parent): STATEMENT:

The firmware shall reject malformed or unauthorized configuration commands.

ACCEPTANCE:

Protocol negative and authorization tests reject invalid writes.

METHOD:

Test

VMODEL_LEVEL:

Software

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

FW-010
48. FW-010 - Firmware UID: FW-010 STATUS: Draft DOMAIN: Firmware PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Every firmware release shall retain build provenance and checksum.

ACCEPTANCE:

Rebuild from pinned inputs reproduces version metadata and artifact hash policy.

METHOD:

Inspection

VMODEL_LEVEL:

Software

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

FW-011
49. FW-011 - Firmware UID: FW-011 STATUS: Draft DOMAIN: Firmware PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

The firmware shall detect stale or invalid temperature data.

ACCEPTANCE:

Loss/stuck-sensor simulated; safe-state policy passes all defined cases.

METHOD:

Test

VMODEL_LEVEL:

Software

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-006

EXECUTION:

Not Run

FW-012
50. FW-012 - Firmware UID: FW-012 STATUS: Draft DOMAIN: Firmware PARENT: SYS-008 RELATIONS (Parent): STATEMENT:

The firmware shall support a controlled calibration data procedure.

ACCEPTANCE:

Calibration revision and CRC verified; corrupt configuration rejected.

METHOD:

Test

VMODEL_LEVEL:

Software

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

MEC-001
51. MEC-001 - Mechanical UID: MEC-001 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-001 RELATIONS (Parent): STATEMENT:

The pack shall secure four cells in the declared CAD orientation.

ACCEPTANCE:

Assembly fit-check agrees with released drawing and stack tolerances.

METHOD:

Inspection

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

MEC-002
52. MEC-002 - Mechanical UID: MEC-002 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-009 RELATIONS (Parent): STATEMENT:

Cell restraints shall comply with the manufacturer compression limits.

ACCEPTANCE:

Worst-case tolerance and clamping force verified against supplier envelope.

METHOD:

Analysis

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

MEC-003
53. MEC-003 - Mechanical UID: MEC-003 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-007 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

Electrical insulation shall prevent accidental busbar-enclosure contact in all specified tolerances.

ACCEPTANCE:

CAD clearance check and physical inspection against frozen spacing standard.

METHOD:

Inspection

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-003

EXECUTION:

Not Run

  • CAD-008
    75. CAD-008 - CAD UID: CAD-008 STATUS: Draft DOMAIN: CAD PARENT: MEC-003 RELATIONS (Parent): STATEMENT:

    CAD automation shall detect electrical/physical clearance rule violations.

    ACCEPTANCE:

    Synthetic interference test produces blocked release and exception record.

    METHOD:

    Test

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

MEC-004
54. MEC-004 - Mechanical UID: MEC-004 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-009 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

The enclosure shall withstand the approved static mounting loads.

ACCEPTANCE:

FEA and representative physical fixture test meet displacement/stress criteria.

METHOD:

Test

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-010

EXECUTION:

Not Run

  • SIM-008
    83. SIM-008 - Simulation UID: SIM-008 STATUS: Draft DOMAIN: Simulation PARENT: MEC-004 RELATIONS (Parent): STATEMENT:

    The structural solver shall support mesh convergence assessment.

    ACCEPTANCE:

    At least three controlled mesh densities compared for critical response.

    METHOD:

    Analysis

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

MEC-005
55. MEC-005 - Mechanical UID: MEC-005 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-009 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

The mounting design shall avoid unacceptable resonances in the operational vibration profile.

ACCEPTANCE:

Modal test correlated to model; resonant response compared to approved limits.

METHOD:

Test

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-013

HAZARD_IDS:

HZ-009, HZ-010

EXECUTION:

Not Run

  • SIM-007
    82. SIM-007 - Simulation UID: SIM-007 STATUS: Draft DOMAIN: Simulation PARENT: MEC-005 RELATIONS (Parent): STATEMENT:

    The structural model shall support eigenfrequency/modal analysis.

    ACCEPTANCE:

    Solver exports frequencies and modes with mesh, materials, constraints manifest.

    METHOD:

    Demo

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

MEC-006
56. MEC-006 - Mechanical UID: MEC-006 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-007 RELATIONS (Parent): STATEMENT:

Busbar fastening shall use controlled fastener and torque specifications.

ACCEPTANCE:

Assembly inspection documents torque procedure, washer and locking approach.

METHOD:

Inspection

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-014

HAZARD_IDS:

HZ-009

EXECUTION:

Not Run

  • STK-008
    8. STK-008 - Stakeholder UID: STK-008 STATUS: Draft DOMAIN: Stakeholder RELATIONS (Child): STATEMENT:

    The product shall be serviceable using documented diagnostics and replaceable assemblies.

    ACCEPTANCE:

    Documented diagnostic workflow identifies each specified field-replaceable assembly.

    METHOD:

    Demo

    VMODEL_LEVEL:

    Validation

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

MEC-007
57. MEC-007 - Mechanical UID: MEC-007 STATUS: Draft DOMAIN: Mechanical PARENT: STK-008 RELATIONS (Parent): STATEMENT:

Serviceable components shall be accessible without disturbing cell terminals unintentionally.

ACCEPTANCE:

Service procedure dry-run demonstrates defined replacement and isolation sequence.

METHOD:

Demo

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

MEC-008
58. MEC-008 - Mechanical UID: MEC-008 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-009 RELATIONS (Parent): STATEMENT:

Mechanical BOM mass shall match CAD estimate within the approved discrepancy limit.

ACCEPTANCE:

As-built pack mass reconciled to CAD/material mass budget.

METHOD:

Test

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

MEC-009
59. MEC-009 - Mechanical UID: MEC-009 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-009 RELATIONS (Parent): STATEMENT:

Critical dimensions and tolerances shall be present in manufacturing drawings.

ACCEPTANCE:

Drawing review verifies dimensions, datum strategy, tolerances and revision labels.

METHOD:

Inspection

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

THM-001
60. THM-001 - Thermal UID: THM-001 STATUS: Draft DOMAIN: Thermal PARENT: SYS-003 RELATIONS (Parent): STATEMENT:

The thermal model shall represent resistive losses in cells and power path.

ACCEPTANCE:

Energy balance and I²R term unit tests pass.

METHOD:

Analysis

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

THM-002
61. THM-002 - Thermal UID: THM-002 STATUS: Draft DOMAIN: Thermal PARENT: SYS-003 RELATIONS (Parent): STATEMENT:

The thermal model shall represent ambient convection and thermal contact paths.

ACCEPTANCE:

Parameters and boundary conditions documented with units and sources.

METHOD:

Inspection

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

THM-003
62. THM-003 - Thermal UID: THM-003 STATUS: Draft DOMAIN: Thermal PARENT: SYS-003 RELATIONS (Parent): STATEMENT:

Thermal response shall be estimated for nominal load and agreed duty cycle.

ACCEPTANCE:

Transient prediction and assumptions exported for each approved scenario.

METHOD:

Analysis

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

THM-004
63. THM-004 - Thermal UID: THM-004 STATUS: Draft DOMAIN: Thermal PARENT: SYS-003 RELATIONS (Parent): STATEMENT:

The hottest measured cell location shall be included in a validation plan.

ACCEPTANCE:

Thermocouple map identifies expected hotspot and representative measurements.

METHOD:

Inspection

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

THM-005
64. THM-005 - Thermal UID: THM-005 STATUS: Draft DOMAIN: Thermal PARENT: SYS-003 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

Thermal simulation accuracy shall be assessed against measured pack temperatures.

ACCEPTANCE:

Correlation error and uncertainty reported across >= 3 agreed load profiles.

METHOD:

Test

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-012

HAZARD_IDS:

HZ-011

EXECUTION:

Not Run

  • SIM-006
    81. SIM-006 - Simulation UID: SIM-006 STATUS: Draft DOMAIN: Simulation PARENT: THM-005 RELATIONS (Parent): STATEMENT:

    The simulation pipeline shall support parameter calibration without overwriting original measurement data.

    ACCEPTANCE:

    Calibrated model version and input dataset hashes recorded separately.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Model

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    EXECUTION:

    Not Run

THM-006
65. THM-006 - Thermal UID: THM-006 STATUS: Draft DOMAIN: Thermal PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

The BMS shall block charging outside the permitted cell thermal range.

ACCEPTANCE:

Boundary fault test shows expected cutoff and recovery behavior.

METHOD:

Test

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-006

EXECUTION:

Not Run

THM-007
66. THM-007 - Thermal UID: THM-007 STATUS: Draft DOMAIN: Thermal PARENT: SYS-005 RELATIONS (Parent): STATEMENT:

The BMS shall block discharge outside the permitted cell thermal range.

ACCEPTANCE:

Boundary fault test shows expected cutoff and recovery behavior.

METHOD:

Test

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

THM-008
67. THM-008 - Thermal UID: THM-008 STATUS: Draft DOMAIN: Thermal PARENT: ELE-009 RELATIONS (Parent): STATEMENT:

Cell balancing heat shall be represented in BMS thermal budget.

ACCEPTANCE:

Worst-case balancing condition analysed and design review approved.

METHOD:

Analysis

VMODEL_LEVEL:

Subsystem

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

CAD-001
68. CAD-001 - CAD UID: CAD-001 STATUS: Draft DOMAIN: CAD PARENT: STK-005 RELATIONS (Parent): STATEMENT:

The master model shall generate the declared pack geometry from controlled parameters.

ACCEPTANCE:

Regenerate 4S nominal variant without manual topology repair.

METHOD:

Demo

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-015

EXECUTION:

Not Run

CAD-002
69. CAD-002 - CAD UID: CAD-002 STATUS: Draft DOMAIN: CAD PARENT: STK-007 RELATIONS (Parent): STATEMENT:

The CAD generator shall support independent series count and cell dimensions within permitted families.

ACCEPTANCE:

Parameterized 4S/8S/16S geometries generated; invalid combinations rejected.

METHOD:

Test

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-016

EXECUTION:

Not Run

CAD-003
70. CAD-003 - CAD UID: CAD-003 STATUS: Draft DOMAIN: CAD PARENT: SYS-001 RELATIONS (Parent): STATEMENT:

Each CAD cell shall reference an approved part geometry and tolerance set.

ACCEPTANCE:

Part ID and dimensions match supplier drawing and imported material record.

METHOD:

Inspection

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • ELE-010
    37. ELE-010 - Electrical UID: ELE-010 STATUS: Draft DOMAIN: Electrical PARENT: SYS-002 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    Battery positive and negative polarity shall be unambiguous at external terminals.

    ACCEPTANCE:

    Drawing, labels and as-built inspection agree.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-004

    EXECUTION:

    Not Run

CAD-004
71. CAD-004 - CAD UID: CAD-004 STATUS: Draft DOMAIN: CAD PARENT: ELE-010 RELATIONS (Parent): STATEMENT:

The CAD assembly shall include terminals, busbars, BMS board, restraints and enclosure.

ACCEPTANCE:

Released exploded assembly lists every defined subassembly.

METHOD:

Inspection

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

CAD-005
72. CAD-005 - CAD UID: CAD-005 STATUS: Draft DOMAIN: CAD PARENT: STK-006 RELATIONS (Parent): STATEMENT:

CAD part quantities shall be reconciled with the engineering BOM.

ACCEPTANCE:

All released CAD component IDs map to counted BOM positions.

METHOD:

Test

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-017

EXECUTION:

Not Run

CAD-006
73. CAD-006 - CAD UID: CAD-006 STATUS: Draft DOMAIN: CAD PARENT: STK-004 RELATIONS (Parent): STATEMENT:

The build pipeline shall publish a browser-inspectable 3D derivative.

ACCEPTANCE:

GLB/glTF derivative opens in target browsers with part IDs and units intact.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

CAD-007
74. CAD-007 - CAD UID: CAD-007 STATUS: Draft DOMAIN: CAD PARENT: STK-005 RELATIONS (Parent): STATEMENT:

CAD outputs shall identify generator version and input parameter revision.

ACCEPTANCE:

Manifest links source file, hash, parameter set and derived file hash.

METHOD:

Inspection

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • MEC-003
    53. MEC-003 - Mechanical UID: MEC-003 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-007 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    Electrical insulation shall prevent accidental busbar-enclosure contact in all specified tolerances.

    ACCEPTANCE:

    CAD clearance check and physical inspection against frozen spacing standard.

    METHOD:

    Inspection

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-003

    EXECUTION:

    Not Run

CAD-008
75. CAD-008 - CAD UID: CAD-008 STATUS: Draft DOMAIN: CAD PARENT: MEC-003 RELATIONS (Parent): STATEMENT:

CAD automation shall detect electrical/physical clearance rule violations.

ACCEPTANCE:

Synthetic interference test produces blocked release and exception record.

METHOD:

Test

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

SIM-001
76. SIM-001 - Simulation UID: SIM-001 STATUS: Draft DOMAIN: Simulation PARENT: STK-005 RELATIONS (Parent): STATEMENT:

The digital twin shall expose a 4-cell electrical equivalent-circuit model.

ACCEPTANCE:

Model responds deterministically to frozen input scenario with baseline output.

METHOD:

Test

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

SIM-002
77. SIM-002 - Simulation UID: SIM-002 STATUS: Draft DOMAIN: Simulation PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Each model run shall record parameter set, solver version and boundary conditions.

ACCEPTANCE:

100% sampled runs reproduce metadata manifest and result hashes.

METHOD:

Inspection

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-011

EXECUTION:

Not Run

SIM-003
78. SIM-003 - Simulation UID: SIM-003 STATUS: Draft DOMAIN: Simulation PARENT: STK-005 RELATIONS (Parent): STATEMENT:

The simulator shall distinguish model predictions from measured test data.

ACCEPTANCE:

UI and exported report mark data origin at sample and series level.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

SIM-004
79. SIM-004 - Simulation UID: SIM-004 STATUS: Draft DOMAIN: Simulation PARENT: STK-005 RELATIONS (Parent): STATEMENT:

The pack model shall report voltage, current, SOC, power and accumulated energy.

ACCEPTANCE:

Numerical conservation/reference checks and display unit tests pass.

METHOD:

Test

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-018

EXECUTION:

Not Run

SIM-005
80. SIM-005 - Simulation UID: SIM-005 STATUS: Draft DOMAIN: Simulation PARENT: STK-005 RELATIONS (Parent): STATEMENT:

The pack model shall evaluate per-cell imbalance.

ACCEPTANCE:

Unbalanced cell synthetic case generates distinct cell states and alerts.

METHOD:

Test

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • THM-005
    64. THM-005 - Thermal UID: THM-005 STATUS: Draft DOMAIN: Thermal PARENT: SYS-003 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    Thermal simulation accuracy shall be assessed against measured pack temperatures.

    ACCEPTANCE:

    Correlation error and uncertainty reported across >= 3 agreed load profiles.

    METHOD:

    Test

    VMODEL_LEVEL:

    System

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-012

    HAZARD_IDS:

    HZ-011

    EXECUTION:

    Not Run

SIM-006
81. SIM-006 - Simulation UID: SIM-006 STATUS: Draft DOMAIN: Simulation PARENT: THM-005 RELATIONS (Parent): STATEMENT:

The simulation pipeline shall support parameter calibration without overwriting original measurement data.

ACCEPTANCE:

Calibrated model version and input dataset hashes recorded separately.

METHOD:

Inspection

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • MEC-005
    55. MEC-005 - Mechanical UID: MEC-005 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-009 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    The mounting design shall avoid unacceptable resonances in the operational vibration profile.

    ACCEPTANCE:

    Modal test correlated to model; resonant response compared to approved limits.

    METHOD:

    Test

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    TEST_IDS:

    TR-013

    HAZARD_IDS:

    HZ-009, HZ-010

    EXECUTION:

    Not Run

SIM-007
82. SIM-007 - Simulation UID: SIM-007 STATUS: Draft DOMAIN: Simulation PARENT: MEC-005 RELATIONS (Parent): STATEMENT:

The structural model shall support eigenfrequency/modal analysis.

ACCEPTANCE:

Solver exports frequencies and modes with mesh, materials, constraints manifest.

METHOD:

Demo

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

  • MEC-004
    54. MEC-004 - Mechanical UID: MEC-004 STATUS: Draft DOMAIN: Mechanical PARENT: SYS-009 RELATIONS (Parent): RELATIONS (Child): STATEMENT:

    The enclosure shall withstand the approved static mounting loads.

    ACCEPTANCE:

    FEA and representative physical fixture test meet displacement/stress criteria.

    METHOD:

    Test

    VMODEL_LEVEL:

    Subsystem

    RELEASE:

    V1-12V

    PRIORITY:

    Must

    OWNER:

    Unassigned

    SOURCE:

    Engineering target - proposed

    HAZARD_IDS:

    HZ-010

    EXECUTION:

    Not Run

SIM-008
83. SIM-008 - Simulation UID: SIM-008 STATUS: Draft DOMAIN: Simulation PARENT: MEC-004 RELATIONS (Parent): STATEMENT:

The structural solver shall support mesh convergence assessment.

ACCEPTANCE:

At least three controlled mesh densities compared for critical response.

METHOD:

Analysis

VMODEL_LEVEL:

Model

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

SIM-009
84. SIM-009 - Simulation UID: SIM-009 STATUS: Draft DOMAIN: Simulation PARENT: STK-004 RELATIONS (Parent): STATEMENT:

Interactive simulation shall return a useful lightweight response within the target UI budget.

ACCEPTANCE:

95th percentile local scenario calculation <2 seconds on target test workstation.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

SIM-010
85. SIM-010 - Simulation UID: SIM-010 STATUS: Draft DOMAIN: Simulation PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Invalid model parameters shall be rejected before execution.

ACCEPTANCE:

Schema/physics guards reject negative resistance, zero mass, bad series count.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-019

EXECUTION:

Not Run

PLT-001
86. PLT-001 - Platform UID: PLT-001 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

Authorized users shall access released projects through modern browsers.

ACCEPTANCE:

Desktop and mobile browser acceptance matrix passes.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

PLT-002
87. PLT-002 - Platform UID: PLT-002 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

Project access shall require authenticated identity and role authorization.

ACCEPTANCE:

Negative tests deny unauthenticated and cross-project access.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-020

EXECUTION:

Not Run

PLT-003
88. PLT-003 - Platform UID: PLT-003 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

Large CAD and simulation artifacts shall be stored in Google Cloud Storage.

ACCEPTANCE:

Artifact upload/download integrity hash matches and metadata indexed.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

PLT-004
89. PLT-004 - Platform UID: PLT-004 STATUS: Draft DOMAIN: Platform PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Requirement documents shall be managed as Git-versioned text sources.

ACCEPTANCE:

A change is traceable to commit, author, diff and review decision.

METHOD:

Inspection

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

PLT-005
90. PLT-005 - Platform UID: PLT-005 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

The UI shall display read-only released CAD model derivatives.

ACCEPTANCE:

Released revision loads and independent user cannot mutate master CAD.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

PLT-006
91. PLT-006 - Platform UID: PLT-006 STATUS: Draft DOMAIN: Platform PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Each simulation result shall reference immutable input and executable versions.

ACCEPTANCE:

Run manifest contains source commit, params checksum, solver version.

METHOD:

Inspection

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

PLT-007
92. PLT-007 - Platform UID: PLT-007 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

Long simulation jobs shall execute outside synchronous web requests.

ACCEPTANCE:

Job survives browser disconnect; status and result remain retrievable.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-021

EXECUTION:

Not Run

PLT-008
93. PLT-008 - Platform UID: PLT-008 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

Cloud storage objects shall be recoverable under the approved backup policy.

ACCEPTANCE:

Documented restore drill recovers deliberately removed test dataset.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-022

HAZARD_IDS:

HZ-015

EXECUTION:

Not Run

PLT-009
94. PLT-009 - Platform UID: PLT-009 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

Remote application secrets shall not be embedded in downloaded browser assets.

ACCEPTANCE:

Security review and secret scanning identify no exposed credentials.

METHOD:

Inspection

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

PLT-010
95. PLT-010 - Platform UID: PLT-010 STATUS: Draft DOMAIN: Platform PARENT: STK-005 RELATIONS (Parent): STATEMENT:

The system shall maintain immutable release manifests.

ACCEPTANCE:

Release includes refs/hashes for requirements, PCB, CAD, FW, BOM, test evidence.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-024

HAZARD_IDS:

HZ-015

EXECUTION:

Not Run

PLT-011
96. PLT-011 - Platform UID: PLT-011 STATUS: Draft DOMAIN: Platform PARENT: STK-005 RELATIONS (Parent): STATEMENT:

The UI shall link each failed test to its governing requirement.

ACCEPTANCE:

Select failed test and navigate to matching requirement ID and commit.

METHOD:

Demo

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

PLT-012
97. PLT-012 - Platform UID: PLT-012 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

The platform shall refuse hazardous remote physical-bench actuation without local enable.

ACCEPTANCE:

Authorization negative test and physical local interlock demonstration pass.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-023

HAZARD_IDS:

HZ-013

EXECUTION:

Not Run

PLT-013
98. PLT-013 - Platform UID: PLT-013 STATUS: Draft DOMAIN: Platform PARENT: STK-005 RELATIONS (Parent): STATEMENT:

The platform shall preserve source measurements separately from derived simulation results.

ACCEPTANCE:

Original datasets content-addressed; transformations separately versioned.

METHOD:

Inspection

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

PLT-014
99. PLT-014 - Platform UID: PLT-014 STATUS: Draft DOMAIN: Platform PARENT: STK-004 RELATIONS (Parent): STATEMENT:

Users shall see run state, errors, and diagnostic references for failed jobs.

ACCEPTANCE:

Forced solver failure yields log link, failure code, and no false 'passed' state.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

VER-001
100. VER-001 - Verification UID: VER-001 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Every approved engineering requirement shall have a verification method and acceptance criterion.

ACCEPTANCE:

No approved requirements have blank method, criterion, or verification ID.

METHOD:

Inspection

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

VER-002
101. VER-002 - Verification UID: VER-002 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Safety-critical requirements shall have a hazard link and review approval.

ACCEPTANCE:

100% safety-tagged requirements linked to at least one risk or safety rationale.

METHOD:

Inspection

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

VER-003
102. VER-003 - Verification UID: VER-003 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Test cases shall identify setup, stimuli, expected result, actual result and artifacts.

ACCEPTANCE:

Sample tests contain all fields and independent rerun possible.

METHOD:

Inspection

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

VER-004
103. VER-004 - Verification UID: VER-004 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Verification results shall distinguish Passed, Failed, Blocked and Not Run.

ACCEPTANCE:

Report schema validation rejects ambiguous status labels.

METHOD:

Test

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

VER-005
104. VER-005 - Verification UID: VER-005 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

The system shall prohibit release on unresolved critical verification failures.

ACCEPTANCE:

Synthetic critical failure blocks release gate automatically.

METHOD:

Test

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-025

EXECUTION:

Not Run

VER-006
105. VER-006 - Verification UID: VER-006 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Test equipment shall be linked to calibration status and uncertainty.

ACCEPTANCE:

Each measurement-based test has instrument ID, calibration date, uncertainty.

METHOD:

Inspection

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

VER-007
106. VER-007 - Verification UID: VER-007 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Requirement changes after baseline shall trigger impact analysis.

ACCEPTANCE:

Diff lists affected architecture elements, CAD, PCB, FW and test IDs.

METHOD:

Demo

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

VER-008
107. VER-008 - Verification UID: VER-008 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

System validation shall be distinguished from specification verification.

ACCEPTANCE:

V&V plan provides separate user-need acceptance and compliance evidence.

METHOD:

Review

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

VER-009
108. VER-009 - Verification UID: VER-009 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Fault injection shall never energize an unguarded hazardous battery bench remotely.

ACCEPTANCE:

Interlock validation rejects remote command in unsafe configuration.

METHOD:

Test

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-013

EXECUTION:

Not Run

VER-010
109. VER-010 - Verification UID: VER-010 STATUS: Draft DOMAIN: Verification PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Regression suites shall run on every controlled software change.

ACCEPTANCE:

CI report records pass/fail, commit and test count for each merge.

METHOD:

Test

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

BOM-001
110. BOM-001 - BOM UID: BOM-001 STATUS: Draft DOMAIN: BOM PARENT: STK-006 RELATIONS (Parent): STATEMENT:

Every approved purchasable part shall have a unique ID and revision.

ACCEPTANCE:

100% released parts have part numbers, approved footprint or spec and revision.

METHOD:

Inspection

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

BOM-002
111. BOM-002 - BOM UID: BOM-002 STATUS: Draft DOMAIN: BOM PARENT: STK-006 RELATIONS (Parent): STATEMENT:

The BOM shall separate cell, BMS, enclosure, harness and assembly cost.

ACCEPTANCE:

Cost rollup correctly sums subassembly and unit totals.

METHOD:

Test

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

BOM-003
112. BOM-003 - BOM UID: BOM-003 STATUS: Draft DOMAIN: BOM PARENT: STK-006 RELATIONS (Parent): STATEMENT:

Unit cost shall be calculated at prototype, 100 and 10000-unit quantities.

ACCEPTANCE:

Cost rollup produces price breaks with quote dates and currency.

METHOD:

Test

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-026

EXECUTION:

Not Run

BOM-004
113. BOM-004 - BOM UID: BOM-004 STATUS: Draft DOMAIN: BOM PARENT: STK-006 RELATIONS (Parent): STATEMENT:

Approved alternates shall preserve form-fit-function and qualification evidence.

ACCEPTANCE:

Replacement cannot be marked approved without referenced validation.

METHOD:

Inspection

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

BOM-005
114. BOM-005 - BOM UID: BOM-005 STATUS: Draft DOMAIN: BOM PARENT: STK-006 RELATIONS (Parent): STATEMENT:

The platform shall flag obsolete or single-source critical parts.

ACCEPTANCE:

Artificial supplier change triggers lifecycle risk flag.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

BOM-006
115. BOM-006 - BOM UID: BOM-006 STATUS: Draft DOMAIN: BOM PARENT: STK-006 RELATIONS (Parent): STATEMENT:

The system shall calculate estimated landed cost using separated assumptions.

ACCEPTANCE:

Formula validation covers price, scrap, assembly, freight and test yield.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

BOM-007
116. BOM-007 - BOM UID: BOM-007 STATUS: Draft DOMAIN: BOM PARENT: STK-006 RELATIONS (Parent): STATEMENT:

Any BOM cost comparison shall identify assumptions and quote validity.

ACCEPTANCE:

100% review samples show quote date and currency normalization.

METHOD:

Inspection

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

MFG-001
117. MFG-001 - Manufacturing UID: MFG-001 STATUS: Draft DOMAIN: Manufacturing PARENT: STK-006 RELATIONS (Parent): STATEMENT:

The pack shall have a defined assembly process with controlled order of operations.

ACCEPTANCE:

Approved work instructions identify each critical step and hazard.

METHOD:

Inspection

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

MFG-002
118. MFG-002 - Manufacturing UID: MFG-002 STATUS: Draft DOMAIN: Manufacturing PARENT: SYS-007 RELATIONS (Parent): STATEMENT:

Pack terminal, fuse and busbar assembly shall have prescribed inspection checks.

ACCEPTANCE:

EOL checklist verifies polarity, continuity and fastener records.

METHOD:

Test

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-004

EXECUTION:

Not Run

MFG-003
119. MFG-003 - Manufacturing UID: MFG-003 STATUS: Draft DOMAIN: Manufacturing PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Each assembled pack shall carry serial and test result identity.

ACCEPTANCE:

Physical label resolves to build record, lot, FW and test data.

METHOD:

Test

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

TEST_IDS:

TR-027

EXECUTION:

Not Run

MFG-004
120. MFG-004 - Manufacturing UID: MFG-004 STATUS: Draft DOMAIN: Manufacturing PARENT: STK-006 RELATIONS (Parent): STATEMENT:

The project shall calculate yield-adjusted production BOM cost.

ACCEPTANCE:

Production estimate formula tests pass for multiple scrap/yield inputs.

METHOD:

Test

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

MFG-005
121. MFG-005 - Manufacturing UID: MFG-005 STATUS: Draft DOMAIN: Manufacturing PARENT: STK-003 RELATIONS (Parent): STATEMENT:

Release documents shall include safe shipping and handling requirements.

ACCEPTANCE:

Reviewed handling procedure and applicable transport compliance matrix exist.

METHOD:

Inspection

VMODEL_LEVEL:

Process

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

MFG-006
122. MFG-006 - Manufacturing UID: MFG-006 STATUS: Draft DOMAIN: Manufacturing PARENT: STK-005 RELATIONS (Parent): STATEMENT:

Firmware programming and configuration shall be logged during end-of-line test.

ACCEPTANCE:

EOL record captures image hash, settings CRC and measured calibration data.

METHOD:

Test

VMODEL_LEVEL:

System

RELEASE:

V1-12V

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

SCL-001
123. SCL-001 - Scale-up UID: SCL-001 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

The family architecture shall separate hardware-dependent protection from portable firmware logic.

ACCEPTANCE:

Design review identifies abstraction interfaces and variant-specific drivers.

METHOD:

Inspection

VMODEL_LEVEL:

Architecture

RELEASE:

V2+

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

SCL-002
124. SCL-002 - Scale-up UID: SCL-002 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

The platform shall reject designs where maximum pack voltage exceeds rated components.

ACCEPTANCE:

Static rule uses cell upper limit * series count against rated design envelope.

METHOD:

Test

VMODEL_LEVEL:

Platform

RELEASE:

V2+

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-014

EXECUTION:

Not Run

SCL-003
125. SCL-003 - Scale-up UID: SCL-003 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

The 8S variant shall receive its own sensing and power protection review.

ACCEPTANCE:

8S architecture sign-off includes sensor, FET, charger, thermal and fuse design.

METHOD:

Review

VMODEL_LEVEL:

Architecture

RELEASE:

V2+

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

SCL-004
126. SCL-004 - Scale-up UID: SCL-004 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

The 16S variant shall receive separate voltage/clearance and protection validation.

ACCEPTANCE:

16S revision has independent electrical and mechanical verification plan.

METHOD:

Review

VMODEL_LEVEL:

Architecture

RELEASE:

V3+

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

SCL-005
127. SCL-005 - Scale-up UID: SCL-005 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

The 72 V-class variant shall define nominal and absolute maximum voltage explicitly.

ACCEPTANCE:

System datasheet declares chemistry, series count and maximum charged voltage.

METHOD:

Inspection

VMODEL_LEVEL:

Architecture

RELEASE:

V4+

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

HAZARD_IDS:

HZ-014

EXECUTION:

Not Run

SCL-006
128. SCL-006 - Scale-up UID: SCL-006 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

Higher-voltage variants shall be assessed for isolation and precharge requirements.

ACCEPTANCE:

Hazard/architecture review documents whether isolation and precharge are needed.

METHOD:

Analysis

VMODEL_LEVEL:

Architecture

RELEASE:

V4+

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

SCL-007
129. SCL-007 - Scale-up UID: SCL-007 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

Variants shall reuse requirement/test templates only after applicability review.

ACCEPTANCE:

Each inherited requirement lists applicable variants and any revised criterion.

METHOD:

Inspection

VMODEL_LEVEL:

Process

RELEASE:

V2+

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run

SCL-008
130. SCL-008 - Scale-up UID: SCL-008 STATUS: Draft DOMAIN: Scale-up PARENT: STK-007 RELATIONS (Parent): STATEMENT:

Series-connected modules shall be validated as one coordinated pack protection system.

ACCEPTANCE:

System fault model reviews worst-case module trip, imbalance, and unintended reclose.

METHOD:

Analysis

VMODEL_LEVEL:

System

RELEASE:

V4+

PRIORITY:

Must

OWNER:

Unassigned

SOURCE:

Engineering target - proposed

EXECUTION:

Not Run