Battery Engineering Platform - Proposed Baseline Rev 0.1
|
Type
|
Level
|
UID
|
STATUS
|
DOMAIN
|
PARENT
|
REFS
|
Title
|
Statement
|
ACCEPTANCE
|
METHOD
|
VMODEL_LEVEL
|
RELEASE
|
PRIORITY
|
OWNER
|
SOURCE
|
TEST_IDS
|
HAZARD_IDS
|
EXECUTION
|
IMPLEMENTATION
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
REQUIREMENT
|
1 |
|
|
|
|
|
The product shall provide a replaceable 12.8 V nominal rechargeable energy source. |
4S1P LFP reference architecture reviewed against intended load. |
Review |
Validation |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
|
REQUIREMENT
|
2 |
|
|
|
|
|
The product shall support an agreed load and charger envelope. |
Electrical load profile and charger profile approved with voltage/current/pulse ranges. |
Review |
Validation |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-005 |
Not Run |
|
|
|
REQUIREMENT
|
3 |
|
|
|
|
|
The product shall prevent hazardous electrical and thermal operating states. |
Hazard review identifies controls and verification for each unacceptable risk. |
Review |
Validation |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
|
REQUIREMENT
|
4 |
|
|
|
|
Children:
|
|
The engineering platform shall allow remote access to released engineering designs. |
Authorized browser can retrieve released CAD view, requirements, BOM, and reports. |
Demo |
Validation |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
5 |
|
|
|
|
Children:
|
|
The platform shall trace design decisions to requirements and verification evidence. |
Sample 10 requirements traced bidirectionally through implementation and test reports. |
Inspection |
Validation |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
6 |
|
|
|
|
|
The project shall maintain a costed production BOM and approved alternatives. |
100% of released purchasable parts have source, quantity, cost and lifecycle status. |
Inspection |
Validation |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
|
REQUIREMENT
|
7 |
|
|
|
|
|
The product family shall support 24 V, 48 V and 72 V-class variants through controlled reuse. |
Family architecture defines reusable and variant-specific assets with no safety assumptions inherited implicitly. |
Review |
Validation |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
|
REQUIREMENT
|
8 |
|
|
|
|
Children:
|
|
The product shall be serviceable using documented diagnostics and replaceable assemblies. |
Documented diagnostic workflow identifies each specified field-replaceable assembly. |
Demo |
Validation |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
9 |
|
|
|
|
Children:
|
|
The product shall meet the environmental and mechanical needs of its intended use. |
Environmental profile and corresponding qualification plan approved. |
Review |
Validation |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
10 |
|
|
|
|
|
|
The project shall support independent review and controlled engineering releases. |
Each released baseline carries approver, version, date and evidence manifest. |
Inspection |
Validation |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
11 |
|
|
|
|
|
The V1 pack shall contain four LFP cells connected in series. |
As-built cell count=4 and measured polarity/topology matches schematic. |
Inspection |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-001 |
|
Not Run |
|
|
|
REQUIREMENT
|
12 |
|
|
|
|
Parents:
Children:
|
|
The V1 reference energy shall be 256 Wh nominal. |
4 × 3.2 V × 20 Ah = 256 Wh in approved reference model. |
Analysis |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
13 |
|
|
|
|
|
The V1 pack shall support 20 A continuous discharge at the specified ambient and SOC. |
Validated steady-state load profile maintained without exceeding approved electrical/thermal limits. |
Test |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
|
REQUIREMENT
|
14 |
|
|
|
|
Parents:
|
|
The V1 pack shall support 10 A charging where the cell supplier permits. |
Charge test at 10 A passes supplier temperature, voltage, and current limits. |
Test |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-005 |
Not Run |
|
|
REQUIREMENT
|
15 |
|
|
|
|
Parents:
Children:
|
|
The pack shall interrupt charge/discharge according to the approved protection state table. |
Each listed fault produces expected output state and recorded event. |
Test |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-004, TR-005 |
HZ-001 |
Not Run |
|
|
REQUIREMENT
|
16 |
|
|
|
|
Parents:
|
|
Pack overcurrent/short-circuit protection shall not depend on a cloud connection. |
Connectivity removed; hardware protection remains functional in supervised bench test. |
Test |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-007 |
HZ-002 |
Not Run |
|
|
REQUIREMENT
|
17 |
|
|
|
|
|
The pack shall incorporate a coordinated fuse and electronic protection concept. |
Safety review validates fuse ratings, FET SOA, fault energy, wiring, and disconnection behavior. |
Analysis |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-002, HZ-007 |
Not Run |
|
|
|
REQUIREMENT
|
18 |
|
|
|
|
|
The pack shall expose a defined service interface for diagnostics. |
All protocol commands pass interface conformance tests. |
Test |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
|
REQUIREMENT
|
19 |
|
|
|
|
|
The pack shall comply with an approved system operating envelope. |
Operating envelope table approved and full boundary-condition test coverage assigned. |
Review |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
|
REQUIREMENT
|
20 |
|
|
|
|
Parents:
|
|
Every completed system test shall identify the tested hardware and firmware revisions. |
Test artifacts contain immutable HW rev, FW hash, instrument calibration, date. |
Inspection |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
21 |
|
|
|
|
Parents:
|
|
Each cell shall be traceable to an approved manufacturer and part number. |
Serial/lot, source datasheet and supplier documented for every prototype cell. |
Inspection |
Component |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-003 |
Not Run |
|
|
REQUIREMENT
|
22 |
|
|
|
|
Parents:
|
|
The selected cell shall provide at least 20 Ah nominal capacity under its specified conditions. |
Manufacturer spec confirmed and capacity acceptance test method approved. |
Test |
Component |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
23 |
|
|
|
|
Parents:
|
|
The design shall prevent cell operation outside supplier charge temperature limits. |
Boundary test inhibits charge as required by frozen cell specification. |
Test |
Component |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
24 |
|
|
|
|
Parents:
|
|
The design shall prevent cell operation outside supplier discharge temperature limits. |
Boundary test inhibits discharge as required by frozen cell specification. |
Test |
Component |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
25 |
|
|
|
|
Parents:
|
|
Cell model parameters shall identify manufacturer, chemistry, revision and test conditions. |
Model dataset contains provenance and temperature/current metadata. |
Inspection |
Component |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
26 |
|
|
|
|
Parents:
|
|
Cell selection shall include a defined matching and incoming quality procedure. |
Incoming inspection evaluates approved capacity, resistance and visual criteria. |
Test |
Component |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
27 |
|
|
|
|
Parents:
|
|
Cell compression and orientation shall conform to supplier mechanical limits. |
Approved fixture and compression specification reviewed against supplier data. |
Inspection |
Component |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
28 |
|
|
|
|
Parents:
Children:
|
|
The system shall measure every series-cell voltage independently. |
Four channels mapped and calibrated against reference instrument. |
Test |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-002 |
HZ-001 |
Not Run |
|
|
REQUIREMENT
|
29 |
|
|
|
|
Parents:
|
|
Cell voltage measurement error shall remain within the approved error budget. |
Measured worst-case absolute error <= frozen sensing accuracy budget. |
Test |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-003 |
|
Not Run |
|
|
REQUIREMENT
|
30 |
|
|
|
|
Parents:
Children:
|
|
Pack current shall be measured in both charge and discharge directions. |
Calibrated positive and negative currents within approved sensing error budget. |
Test |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
31 |
|
|
|
|
Parents:
|
|
The system shall detect an open cell-sense lead or enter a defined safe state. |
Each applicable sense-lead disconnect produces mapped fault/safe state. |
Test |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-006 |
HZ-008 |
Not Run |
|
|
REQUIREMENT
|
32 |
|
|
|
|
Parents:
|
|
Protection switches shall withstand approved continuous, pulse and fault operating cases. |
Thermal, SOA and transient calculations signed off; representative tests pass. |
Analysis |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-007 |
Not Run |
|
|
REQUIREMENT
|
33 |
|
|
|
|
Parents:
|
|
The battery shall have a fuse coordinated with conductor and fault energy limits. |
Fuse I²t, expected prospective short current and conductor limits reviewed. |
Analysis |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
34 |
|
|
|
|
Parents:
|
|
Diagnostic connector pinout shall be keyed and defined. |
ICD and physical inspection show no ambiguous voltage/polarity connections. |
Inspection |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
35 |
|
|
|
|
Parents:
|
|
PCB creepage, clearance and trace geometry shall meet the approved design rules. |
Automated DRC zero blockers; independent safety spacing review passed. |
Inspection |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
36 |
|
|
|
|
Parents:
Children:
|
|
The BMS shall support a documented balancing strategy. |
Balancing activation, inhibition, current and thermal budget tested. |
Test |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-011 |
|
Not Run |
|
|
REQUIREMENT
|
37 |
|
|
|
|
Parents:
Children:
|
|
Battery positive and negative polarity shall be unambiguous at external terminals. |
Drawing, labels and as-built inspection agree. |
Inspection |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-004 |
Not Run |
|
|
REQUIREMENT
|
38 |
|
|
|
|
Parents:
|
|
BMS power consumption shall remain within an approved storage and standby budget. |
Measured operating/sleep current versus frozen current budget. |
Test |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
39 |
|
|
|
|
Parents:
|
|
The firmware shall implement explicit INIT, IDLE, CHARGE, DISCHARGE, FAULT and SLEEP states. |
All allowed and forbidden transitions covered by automated state table tests. |
Test |
Software |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-008 |
|
Not Run |
|
|
REQUIREMENT
|
40 |
|
|
|
|
Parents:
|
|
The firmware shall not override autonomous hardware protection to enable unsafe current. |
Fault injection demonstrates external commands cannot bypass hardware protection. |
Test |
Software |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-009 |
HZ-012 |
Not Run |
|
|
REQUIREMENT
|
41 |
|
|
|
|
Parents:
|
|
The firmware shall acquire and validate per-cell voltage samples. |
Unit tests cover scaling, range checking, invalid data and stale samples. |
Test |
Software |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
42 |
|
|
|
|
Parents:
|
|
The firmware shall maintain a signed coulomb-counting current integral. |
Synthetic charge/discharge traces reproduce expected integrated Ah within numerical tolerance. |
Test |
Software |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-010 |
|
Not Run |
|
|
REQUIREMENT
|
43 |
|
|
|
|
Parents:
|
|
The firmware shall expose versioned diagnostic telemetry. |
Protocol tests validate schema, units, timestamps and version negotiation. |
Test |
Software |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
44 |
|
|
|
|
Parents:
|
|
The firmware shall inhibit balancing under disallowed thermal/electrical states. |
State-based tests cover all balancing inhibit conditions. |
Test |
Software |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
45 |
|
|
|
|
Parents:
|
|
The firmware shall retain a fault cause across a reset when specified by fault policy. |
Reset/power-cycle test demonstrates event persists until authorized clearing. |
Test |
Software |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
46 |
|
|
|
|
Parents:
|
|
The firmware shall detect stalled critical tasks through watchdog supervision. |
Injected task stall leads to defined fail-safe outcome. |
Test |
Software |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-012 |
Not Run |
|
|
REQUIREMENT
|
47 |
|
|
|
|
Parents:
|
|
The firmware shall reject malformed or unauthorized configuration commands. |
Protocol negative and authorization tests reject invalid writes. |
Test |
Software |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
48 |
|
|
|
|
Parents:
|
|
Every firmware release shall retain build provenance and checksum. |
Rebuild from pinned inputs reproduces version metadata and artifact hash policy. |
Inspection |
Software |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
49 |
|
|
|
|
Parents:
|
|
The firmware shall detect stale or invalid temperature data. |
Loss/stuck-sensor simulated; safe-state policy passes all defined cases. |
Test |
Software |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-006 |
Not Run |
|
|
REQUIREMENT
|
50 |
|
|
|
|
Parents:
|
|
The firmware shall support a controlled calibration data procedure. |
Calibration revision and CRC verified; corrupt configuration rejected. |
Test |
Software |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
51 |
|
|
|
|
Parents:
|
|
The pack shall secure four cells in the declared CAD orientation. |
Assembly fit-check agrees with released drawing and stack tolerances. |
Inspection |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
52 |
|
|
|
|
Parents:
|
|
Cell restraints shall comply with the manufacturer compression limits. |
Worst-case tolerance and clamping force verified against supplier envelope. |
Analysis |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
53 |
|
|
|
|
Parents:
Children:
|
|
Electrical insulation shall prevent accidental busbar-enclosure contact in all specified tolerances. |
CAD clearance check and physical inspection against frozen spacing standard. |
Inspection |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-003 |
Not Run |
|
|
REQUIREMENT
|
54 |
|
|
|
|
Parents:
Children:
|
|
The enclosure shall withstand the approved static mounting loads. |
FEA and representative physical fixture test meet displacement/stress criteria. |
Test |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-010 |
Not Run |
|
|
REQUIREMENT
|
55 |
|
|
|
|
Parents:
Children:
|
|
The mounting design shall avoid unacceptable resonances in the operational vibration profile. |
Modal test correlated to model; resonant response compared to approved limits. |
Test |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-013 |
HZ-009, HZ-010 |
Not Run |
|
|
REQUIREMENT
|
56 |
|
|
|
|
Parents:
|
|
Busbar fastening shall use controlled fastener and torque specifications. |
Assembly inspection documents torque procedure, washer and locking approach. |
Inspection |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-014 |
HZ-009 |
Not Run |
|
|
REQUIREMENT
|
57 |
|
|
|
|
Parents:
|
|
Serviceable components shall be accessible without disturbing cell terminals unintentionally. |
Service procedure dry-run demonstrates defined replacement and isolation sequence. |
Demo |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
58 |
|
|
|
|
Parents:
|
|
Mechanical BOM mass shall match CAD estimate within the approved discrepancy limit. |
As-built pack mass reconciled to CAD/material mass budget. |
Test |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
59 |
|
|
|
|
Parents:
|
|
Critical dimensions and tolerances shall be present in manufacturing drawings. |
Drawing review verifies dimensions, datum strategy, tolerances and revision labels. |
Inspection |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
60 |
|
|
|
|
Parents:
|
|
The thermal model shall represent resistive losses in cells and power path. |
Energy balance and I²R term unit tests pass. |
Analysis |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
61 |
|
|
|
|
Parents:
|
|
The thermal model shall represent ambient convection and thermal contact paths. |
Parameters and boundary conditions documented with units and sources. |
Inspection |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
62 |
|
|
|
|
Parents:
|
|
Thermal response shall be estimated for nominal load and agreed duty cycle. |
Transient prediction and assumptions exported for each approved scenario. |
Analysis |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
63 |
|
|
|
|
Parents:
|
|
The hottest measured cell location shall be included in a validation plan. |
Thermocouple map identifies expected hotspot and representative measurements. |
Inspection |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
64 |
|
|
|
|
Parents:
Children:
|
|
Thermal simulation accuracy shall be assessed against measured pack temperatures. |
Correlation error and uncertainty reported across >= 3 agreed load profiles. |
Test |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-012 |
HZ-011 |
Not Run |
|
|
REQUIREMENT
|
65 |
|
|
|
|
Parents:
|
|
The BMS shall block charging outside the permitted cell thermal range. |
Boundary fault test shows expected cutoff and recovery behavior. |
Test |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-006 |
Not Run |
|
|
REQUIREMENT
|
66 |
|
|
|
|
Parents:
|
|
The BMS shall block discharge outside the permitted cell thermal range. |
Boundary fault test shows expected cutoff and recovery behavior. |
Test |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
67 |
|
|
|
|
Parents:
|
|
Cell balancing heat shall be represented in BMS thermal budget. |
Worst-case balancing condition analysed and design review approved. |
Analysis |
Subsystem |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
68 |
|
|
|
|
Parents:
|
|
The master model shall generate the declared pack geometry from controlled parameters. |
Regenerate 4S nominal variant without manual topology repair. |
Demo |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-015 |
|
Not Run |
|
|
REQUIREMENT
|
69 |
|
|
|
|
Parents:
|
|
The CAD generator shall support independent series count and cell dimensions within permitted families. |
Parameterized 4S/8S/16S geometries generated; invalid combinations rejected. |
Test |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-016 |
|
Not Run |
|
|
REQUIREMENT
|
70 |
|
|
|
|
Parents:
|
|
Each CAD cell shall reference an approved part geometry and tolerance set. |
Part ID and dimensions match supplier drawing and imported material record. |
Inspection |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
71 |
|
|
|
|
Parents:
|
|
The CAD assembly shall include terminals, busbars, BMS board, restraints and enclosure. |
Released exploded assembly lists every defined subassembly. |
Inspection |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
72 |
|
|
|
|
Parents:
|
|
CAD part quantities shall be reconciled with the engineering BOM. |
All released CAD component IDs map to counted BOM positions. |
Test |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-017 |
|
Not Run |
|
|
REQUIREMENT
|
73 |
|
|
|
|
Parents:
|
|
The build pipeline shall publish a browser-inspectable 3D derivative. |
GLB/glTF derivative opens in target browsers with part IDs and units intact. |
Test |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
74 |
|
|
|
|
Parents:
|
|
CAD outputs shall identify generator version and input parameter revision. |
Manifest links source file, hash, parameter set and derived file hash. |
Inspection |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
75 |
|
|
|
|
Parents:
|
|
CAD automation shall detect electrical/physical clearance rule violations. |
Synthetic interference test produces blocked release and exception record. |
Test |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
76 |
|
|
|
|
Parents:
|
|
The digital twin shall expose a 4-cell electrical equivalent-circuit model. |
Model responds deterministically to frozen input scenario with baseline output. |
Test |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
77 |
|
|
|
|
Parents:
|
|
Each model run shall record parameter set, solver version and boundary conditions. |
100% sampled runs reproduce metadata manifest and result hashes. |
Inspection |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-011 |
Not Run |
|
|
REQUIREMENT
|
78 |
|
|
|
|
Parents:
|
|
The simulator shall distinguish model predictions from measured test data. |
UI and exported report mark data origin at sample and series level. |
Test |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
79 |
|
|
|
|
Parents:
|
|
The pack model shall report voltage, current, SOC, power and accumulated energy. |
Numerical conservation/reference checks and display unit tests pass. |
Test |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-018 |
|
Not Run |
|
|
REQUIREMENT
|
80 |
|
|
|
|
Parents:
|
|
The pack model shall evaluate per-cell imbalance. |
Unbalanced cell synthetic case generates distinct cell states and alerts. |
Test |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
81 |
|
|
|
|
Parents:
|
|
The simulation pipeline shall support parameter calibration without overwriting original measurement data. |
Calibrated model version and input dataset hashes recorded separately. |
Inspection |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
82 |
|
|
|
|
Parents:
|
|
The structural model shall support eigenfrequency/modal analysis. |
Solver exports frequencies and modes with mesh, materials, constraints manifest. |
Demo |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
83 |
|
|
|
|
Parents:
|
|
The structural solver shall support mesh convergence assessment. |
At least three controlled mesh densities compared for critical response. |
Analysis |
Model |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
84 |
|
|
|
|
Parents:
|
|
Interactive simulation shall return a useful lightweight response within the target UI budget. |
95th percentile local scenario calculation <2 seconds on target test workstation. |
Test |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
85 |
|
|
|
|
Parents:
|
|
Invalid model parameters shall be rejected before execution. |
Schema/physics guards reject negative resistance, zero mass, bad series count. |
Test |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-019 |
|
Not Run |
|
|
REQUIREMENT
|
86 |
|
|
|
|
Parents:
|
|
Authorized users shall access released projects through modern browsers. |
Desktop and mobile browser acceptance matrix passes. |
Test |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
87 |
|
|
|
|
Parents:
|
|
Project access shall require authenticated identity and role authorization. |
Negative tests deny unauthenticated and cross-project access. |
Test |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-020 |
|
Not Run |
|
|
REQUIREMENT
|
88 |
|
|
|
|
Parents:
|
|
Large CAD and simulation artifacts shall be stored in Google Cloud Storage. |
Artifact upload/download integrity hash matches and metadata indexed. |
Test |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
89 |
|
|
|
|
Parents:
|
|
Requirement documents shall be managed as Git-versioned text sources. |
A change is traceable to commit, author, diff and review decision. |
Inspection |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
90 |
|
|
|
|
Parents:
|
|
The UI shall display read-only released CAD model derivatives. |
Released revision loads and independent user cannot mutate master CAD. |
Test |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
91 |
|
|
|
|
Parents:
|
|
Each simulation result shall reference immutable input and executable versions. |
Run manifest contains source commit, params checksum, solver version. |
Inspection |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
92 |
|
|
|
|
Parents:
|
|
Long simulation jobs shall execute outside synchronous web requests. |
Job survives browser disconnect; status and result remain retrievable. |
Test |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-021 |
|
Not Run |
|
|
REQUIREMENT
|
93 |
|
|
|
|
Parents:
|
|
Cloud storage objects shall be recoverable under the approved backup policy. |
Documented restore drill recovers deliberately removed test dataset. |
Test |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-022 |
HZ-015 |
Not Run |
|
|
REQUIREMENT
|
94 |
|
|
|
|
Parents:
|
|
Remote application secrets shall not be embedded in downloaded browser assets. |
Security review and secret scanning identify no exposed credentials. |
Inspection |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
95 |
|
|
|
|
Parents:
|
|
The system shall maintain immutable release manifests. |
Release includes refs/hashes for requirements, PCB, CAD, FW, BOM, test evidence. |
Test |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-024 |
HZ-015 |
Not Run |
|
|
REQUIREMENT
|
96 |
|
|
|
|
Parents:
|
|
The UI shall link each failed test to its governing requirement. |
Select failed test and navigate to matching requirement ID and commit. |
Demo |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
97 |
|
|
|
|
Parents:
|
|
The platform shall refuse hazardous remote physical-bench actuation without local enable. |
Authorization negative test and physical local interlock demonstration pass. |
Test |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-023 |
HZ-013 |
Not Run |
|
|
REQUIREMENT
|
98 |
|
|
|
|
Parents:
|
|
The platform shall preserve source measurements separately from derived simulation results. |
Original datasets content-addressed; transformations separately versioned. |
Inspection |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
99 |
|
|
|
|
Parents:
|
|
Users shall see run state, errors, and diagnostic references for failed jobs. |
Forced solver failure yields log link, failure code, and no false 'passed' state. |
Test |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
100 |
|
|
|
|
Parents:
|
|
Every approved engineering requirement shall have a verification method and acceptance criterion. |
No approved requirements have blank method, criterion, or verification ID. |
Inspection |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
101 |
|
|
|
|
Parents:
|
|
Safety-critical requirements shall have a hazard link and review approval. |
100% safety-tagged requirements linked to at least one risk or safety rationale. |
Inspection |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
102 |
|
|
|
|
Parents:
|
|
Test cases shall identify setup, stimuli, expected result, actual result and artifacts. |
Sample tests contain all fields and independent rerun possible. |
Inspection |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
103 |
|
|
|
|
Parents:
|
|
Verification results shall distinguish Passed, Failed, Blocked and Not Run. |
Report schema validation rejects ambiguous status labels. |
Test |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
104 |
|
|
|
|
Parents:
|
|
The system shall prohibit release on unresolved critical verification failures. |
Synthetic critical failure blocks release gate automatically. |
Test |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-025 |
|
Not Run |
|
|
REQUIREMENT
|
105 |
|
|
|
|
Parents:
|
|
Test equipment shall be linked to calibration status and uncertainty. |
Each measurement-based test has instrument ID, calibration date, uncertainty. |
Inspection |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
106 |
|
|
|
|
Parents:
|
|
Requirement changes after baseline shall trigger impact analysis. |
Diff lists affected architecture elements, CAD, PCB, FW and test IDs. |
Demo |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
107 |
|
|
|
|
Parents:
|
|
System validation shall be distinguished from specification verification. |
V&V plan provides separate user-need acceptance and compliance evidence. |
Review |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
108 |
|
|
|
|
Parents:
|
|
Fault injection shall never energize an unguarded hazardous battery bench remotely. |
Interlock validation rejects remote command in unsafe configuration. |
Test |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-013 |
Not Run |
|
|
REQUIREMENT
|
109 |
|
|
|
|
Parents:
|
|
Regression suites shall run on every controlled software change. |
CI report records pass/fail, commit and test count for each merge. |
Test |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
110 |
|
|
|
|
Parents:
|
|
Every approved purchasable part shall have a unique ID and revision. |
100% released parts have part numbers, approved footprint or spec and revision. |
Inspection |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
111 |
|
|
|
|
Parents:
|
|
The BOM shall separate cell, BMS, enclosure, harness and assembly cost. |
Cost rollup correctly sums subassembly and unit totals. |
Test |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
112 |
|
|
|
|
Parents:
|
|
Unit cost shall be calculated at prototype, 100 and 10000-unit quantities. |
Cost rollup produces price breaks with quote dates and currency. |
Test |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-026 |
|
Not Run |
|
|
REQUIREMENT
|
113 |
|
|
|
|
Parents:
|
|
Approved alternates shall preserve form-fit-function and qualification evidence. |
Replacement cannot be marked approved without referenced validation. |
Inspection |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
114 |
|
|
|
|
Parents:
|
|
The platform shall flag obsolete or single-source critical parts. |
Artificial supplier change triggers lifecycle risk flag. |
Test |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
115 |
|
|
|
|
Parents:
|
|
The system shall calculate estimated landed cost using separated assumptions. |
Formula validation covers price, scrap, assembly, freight and test yield. |
Test |
Platform |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
116 |
|
|
|
|
Parents:
|
|
Any BOM cost comparison shall identify assumptions and quote validity. |
100% review samples show quote date and currency normalization. |
Inspection |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
117 |
|
|
|
|
Parents:
|
|
The pack shall have a defined assembly process with controlled order of operations. |
Approved work instructions identify each critical step and hazard. |
Inspection |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
118 |
|
|
|
|
Parents:
|
|
Pack terminal, fuse and busbar assembly shall have prescribed inspection checks. |
EOL checklist verifies polarity, continuity and fastener records. |
Test |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-004 |
Not Run |
|
|
REQUIREMENT
|
119 |
|
|
|
|
Parents:
|
|
Each assembled pack shall carry serial and test result identity. |
Physical label resolves to build record, lot, FW and test data. |
Test |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
TR-027 |
|
Not Run |
|
|
REQUIREMENT
|
120 |
|
|
|
|
Parents:
|
|
The project shall calculate yield-adjusted production BOM cost. |
Production estimate formula tests pass for multiple scrap/yield inputs. |
Test |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
121 |
|
|
|
|
Parents:
|
|
Release documents shall include safe shipping and handling requirements. |
Reviewed handling procedure and applicable transport compliance matrix exist. |
Inspection |
Process |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
122 |
|
|
|
|
Parents:
|
|
Firmware programming and configuration shall be logged during end-of-line test. |
EOL record captures image hash, settings CRC and measured calibration data. |
Test |
System |
V1-12V |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
123 |
|
|
|
|
Parents:
|
|
The family architecture shall separate hardware-dependent protection from portable firmware logic. |
Design review identifies abstraction interfaces and variant-specific drivers. |
Inspection |
Architecture |
V2+ |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
124 |
|
|
|
|
Parents:
|
|
The platform shall reject designs where maximum pack voltage exceeds rated components. |
Static rule uses cell upper limit * series count against rated design envelope. |
Test |
Platform |
V2+ |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-014 |
Not Run |
|
|
REQUIREMENT
|
125 |
|
|
|
|
Parents:
|
|
The 8S variant shall receive its own sensing and power protection review. |
8S architecture sign-off includes sensor, FET, charger, thermal and fuse design. |
Review |
Architecture |
V2+ |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
126 |
|
|
|
|
Parents:
|
|
The 16S variant shall receive separate voltage/clearance and protection validation. |
16S revision has independent electrical and mechanical verification plan. |
Review |
Architecture |
V3+ |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
127 |
|
|
|
|
Parents:
|
|
The 72 V-class variant shall define nominal and absolute maximum voltage explicitly. |
System datasheet declares chemistry, series count and maximum charged voltage. |
Inspection |
Architecture |
V4+ |
Must |
Unassigned |
Engineering target - proposed |
|
HZ-014 |
Not Run |
|
|
REQUIREMENT
|
128 |
|
|
|
|
Parents:
|
|
Higher-voltage variants shall be assessed for isolation and precharge requirements. |
Hazard/architecture review documents whether isolation and precharge are needed. |
Analysis |
Architecture |
V4+ |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
129 |
|
|
|
|
Parents:
|
|
Variants shall reuse requirement/test templates only after applicability review. |
Each inherited requirement lists applicable variants and any revised criterion. |
Inspection |
Process |
V2+ |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|
|
REQUIREMENT
|
130 |
|
|
|
|
Parents:
|
|
Series-connected modules shall be validated as one coordinated pack protection system. |
System fault model reviews worst-case module trip, imbalance, and unintended reclose. |
Analysis |
System |
V4+ |
Must |
Unassigned |
Engineering target - proposed |
|
|
Not Run |
|