The product shall provide a replaceable 12.8 V nominal rechargeable energy source.
-
11. SYS-001 - System SYS-001 The V1 pack shall contain four LFP cells connected in series.
-
21. CEL-001 - Cell CEL-001 Each cell shall be traceable to an approved manufacturer and part number.
-
22. CEL-002 - Cell CEL-002 The selected cell shall provide at least 20 Ah nominal capacity under its specified conditions.
-
25. CEL-005 - Cell CEL-005 Cell model parameters shall identify manufacturer, chemistry, revision and test conditions.
-
26. CEL-006 - Cell CEL-006 Cell selection shall include a defined matching and incoming quality procedure.
-
51. MEC-001 - Mechanical MEC-001 The pack shall secure four cells in the declared CAD orientation.
-
70. CAD-003 - CAD CAD-003 Each CAD cell shall reference an approved part geometry and tolerance set.
-
-
12. SYS-002 - System SYS-002 The V1 reference energy shall be 256 Wh nominal.
-
37. ELE-010 - Electrical ELE-010 Battery positive and negative polarity shall be unambiguous at external terminals.
-
71. CAD-004 - CAD CAD-004 The CAD assembly shall include terminals, busbars, BMS board, restraints and enclosure.
-
-
The product shall support an agreed load and charger envelope.
-
13. SYS-003 - System SYS-003 The V1 pack shall support 20 A continuous discharge at the specified ambient and SOC.
-
60. THM-001 - Thermal THM-001 The thermal model shall represent resistive losses in cells and power path.
-
61. THM-002 - Thermal THM-002 The thermal model shall represent ambient convection and thermal contact paths.
-
62. THM-003 - Thermal THM-003 Thermal response shall be estimated for nominal load and agreed duty cycle.
-
63. THM-004 - Thermal THM-004 The hottest measured cell location shall be included in a validation plan.
-
64. THM-005 - Thermal THM-005 Thermal simulation accuracy shall be assessed against measured pack temperatures.
-
81. SIM-006 - Simulation SIM-006 The simulation pipeline shall support parameter calibration without overwriting original measurement data.
-
-
-
14. SYS-004 - System SYS-004 The V1 pack shall support 10 A charging where the cell supplier permits.
-
18. SYS-008 - System SYS-008 The pack shall expose a defined service interface for diagnostics.
-
34. ELE-007 - Electrical ELE-007 Diagnostic connector pinout shall be keyed and defined.
-
43. FW-005 - Firmware FW-005 The firmware shall expose versioned diagnostic telemetry.
-
47. FW-009 - Firmware FW-009 The firmware shall reject malformed or unauthorized configuration commands.
-
50. FW-012 - Firmware FW-012 The firmware shall support a controlled calibration data procedure.
-
The product shall prevent hazardous electrical and thermal operating states.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
28. ELE-001 - Electrical ELE-001 The system shall measure every series-cell voltage independently.
-
41. FW-003 - Firmware FW-003 The firmware shall acquire and validate per-cell voltage samples.
-
-
29. ELE-002 - Electrical ELE-002 Cell voltage measurement error shall remain within the approved error budget.
-
30. ELE-003 - Electrical ELE-003 Pack current shall be measured in both charge and discharge directions.
-
42. FW-004 - Firmware FW-004 The firmware shall maintain a signed coulomb-counting current integral.
-
-
31. ELE-004 - Electrical ELE-004 The system shall detect an open cell-sense lead or enter a defined safe state.
-
36. ELE-009 - Electrical ELE-009 The BMS shall support a documented balancing strategy.
-
44. FW-006 - Firmware FW-006 The firmware shall inhibit balancing under disallowed thermal/electrical states.
-
67. THM-008 - Thermal THM-008 Cell balancing heat shall be represented in BMS thermal budget.
-
-
38. ELE-011 - Electrical ELE-011 BMS power consumption shall remain within an approved storage and standby budget.
-
39. FW-001 - Firmware FW-001 The firmware shall implement explicit INIT, IDLE, CHARGE, DISCHARGE, FAULT and SLEEP states.
-
40. FW-002 - Firmware FW-002 The firmware shall not override autonomous hardware protection to enable unsafe current.
-
45. FW-007 - Firmware FW-007 The firmware shall retain a fault cause across a reset when specified by fault policy.
-
46. FW-008 - Firmware FW-008 The firmware shall detect stalled critical tasks through watchdog supervision.
-
49. FW-011 - Firmware FW-011 The firmware shall detect stale or invalid temperature data.
-
65. THM-006 - Thermal THM-006 The BMS shall block charging outside the permitted cell thermal range.
-
66. THM-007 - Thermal THM-007 The BMS shall block discharge outside the permitted cell thermal range.
-
-
16. SYS-006 - System SYS-006 Pack overcurrent/short-circuit protection shall not depend on a cloud connection.
-
17. SYS-007 - System SYS-007 The pack shall incorporate a coordinated fuse and electronic protection concept.
-
32. ELE-005 - Electrical ELE-005 Protection switches shall withstand approved continuous, pulse and fault operating cases.
-
33. ELE-006 - Electrical ELE-006 The battery shall have a fuse coordinated with conductor and fault energy limits.
-
53. MEC-003 - Mechanical MEC-003 Electrical insulation shall prevent accidental busbar-enclosure contact in all specified tolerances.
-
75. CAD-008 - CAD CAD-008 CAD automation shall detect electrical/physical clearance rule violations.
-
-
56. MEC-006 - Mechanical MEC-006 Busbar fastening shall use controlled fastener and torque specifications.
-
118. MFG-002 - Manufacturing MFG-002 Pack terminal, fuse and busbar assembly shall have prescribed inspection checks.
-
-
121. MFG-005 - Manufacturing MFG-005 Release documents shall include safe shipping and handling requirements.
The engineering platform shall allow remote access to released engineering designs.
-
73. CAD-006 - CAD CAD-006 The build pipeline shall publish a browser-inspectable 3D derivative.
-
84. SIM-009 - Simulation SIM-009 Interactive simulation shall return a useful lightweight response within the target UI budget.
-
86. PLT-001 - Platform PLT-001 Authorized users shall access released projects through modern browsers.
-
87. PLT-002 - Platform PLT-002 Project access shall require authenticated identity and role authorization.
-
88. PLT-003 - Platform PLT-003 Large CAD and simulation artifacts shall be stored in Google Cloud Storage.
-
90. PLT-005 - Platform PLT-005 The UI shall display read-only released CAD model derivatives.
-
92. PLT-007 - Platform PLT-007 Long simulation jobs shall execute outside synchronous web requests.
-
93. PLT-008 - Platform PLT-008 Cloud storage objects shall be recoverable under the approved backup policy.
-
94. PLT-009 - Platform PLT-009 Remote application secrets shall not be embedded in downloaded browser assets.
-
97. PLT-012 - Platform PLT-012 The platform shall refuse hazardous remote physical-bench actuation without local enable.
-
99. PLT-014 - Platform PLT-014 Users shall see run state, errors, and diagnostic references for failed jobs.
The platform shall trace design decisions to requirements and verification evidence.
-
20. SYS-010 - System SYS-010 Every completed system test shall identify the tested hardware and firmware revisions.
-
48. FW-010 - Firmware FW-010 Every firmware release shall retain build provenance and checksum.
-
68. CAD-001 - CAD CAD-001 The master model shall generate the declared pack geometry from controlled parameters.
-
74. CAD-007 - CAD CAD-007 CAD outputs shall identify generator version and input parameter revision.
-
76. SIM-001 - Simulation SIM-001 The digital twin shall expose a 4-cell electrical equivalent-circuit model.
-
77. SIM-002 - Simulation SIM-002 Each model run shall record parameter set, solver version and boundary conditions.
-
78. SIM-003 - Simulation SIM-003 The simulator shall distinguish model predictions from measured test data.
-
79. SIM-004 - Simulation SIM-004 The pack model shall report voltage, current, SOC, power and accumulated energy.
-
80. SIM-005 - Simulation SIM-005 The pack model shall evaluate per-cell imbalance.
-
85. SIM-010 - Simulation SIM-010 Invalid model parameters shall be rejected before execution.
-
89. PLT-004 - Platform PLT-004 Requirement documents shall be managed as Git-versioned text sources.
-
91. PLT-006 - Platform PLT-006 Each simulation result shall reference immutable input and executable versions.
-
95. PLT-010 - Platform PLT-010 The system shall maintain immutable release manifests.
-
96. PLT-011 - Platform PLT-011 The UI shall link each failed test to its governing requirement.
-
98. PLT-013 - Platform PLT-013 The platform shall preserve source measurements separately from derived simulation results.
-
100. VER-001 - Verification VER-001 Every approved engineering requirement shall have a verification method and acceptance criterion.
-
101. VER-002 - Verification VER-002 Safety-critical requirements shall have a hazard link and review approval.
-
102. VER-003 - Verification VER-003 Test cases shall identify setup, stimuli, expected result, actual result and artifacts.
-
103. VER-004 - Verification VER-004 Verification results shall distinguish Passed, Failed, Blocked and Not Run.
-
104. VER-005 - Verification VER-005 The system shall prohibit release on unresolved critical verification failures.
-
105. VER-006 - Verification VER-006 Test equipment shall be linked to calibration status and uncertainty.
-
106. VER-007 - Verification VER-007 Requirement changes after baseline shall trigger impact analysis.
-
107. VER-008 - Verification VER-008 System validation shall be distinguished from specification verification.
-
108. VER-009 - Verification VER-009 Fault injection shall never energize an unguarded hazardous battery bench remotely.
-
109. VER-010 - Verification VER-010 Regression suites shall run on every controlled software change.
-
119. MFG-003 - Manufacturing MFG-003 Each assembled pack shall carry serial and test result identity.
-
122. MFG-006 - Manufacturing MFG-006 Firmware programming and configuration shall be logged during end-of-line test.
The project shall maintain a costed production BOM and approved alternatives.
-
72. CAD-005 - CAD CAD-005 CAD part quantities shall be reconciled with the engineering BOM.
-
110. BOM-001 - BOM BOM-001 Every approved purchasable part shall have a unique ID and revision.
-
111. BOM-002 - BOM BOM-002 The BOM shall separate cell, BMS, enclosure, harness and assembly cost.
-
112. BOM-003 - BOM BOM-003 Unit cost shall be calculated at prototype, 100 and 10000-unit quantities.
-
113. BOM-004 - BOM BOM-004 Approved alternates shall preserve form-fit-function and qualification evidence.
-
114. BOM-005 - BOM BOM-005 The platform shall flag obsolete or single-source critical parts.
-
115. BOM-006 - BOM BOM-006 The system shall calculate estimated landed cost using separated assumptions.
-
116. BOM-007 - BOM BOM-007 Any BOM cost comparison shall identify assumptions and quote validity.
-
117. MFG-001 - Manufacturing MFG-001 The pack shall have a defined assembly process with controlled order of operations.
-
120. MFG-004 - Manufacturing MFG-004 The project shall calculate yield-adjusted production BOM cost.
The product family shall support 24 V, 48 V and 72 V-class variants through controlled reuse.
-
69. CAD-002 - CAD CAD-002 The CAD generator shall support independent series count and cell dimensions within permitted families.
-
123. SCL-001 - Scale-up SCL-001 The family architecture shall separate hardware-dependent protection from portable firmware logic.
-
124. SCL-002 - Scale-up SCL-002 The platform shall reject designs where maximum pack voltage exceeds rated components.
-
125. SCL-003 - Scale-up SCL-003 The 8S variant shall receive its own sensing and power protection review.
-
126. SCL-004 - Scale-up SCL-004 The 16S variant shall receive separate voltage/clearance and protection validation.
-
127. SCL-005 - Scale-up SCL-005 The 72 V-class variant shall define nominal and absolute maximum voltage explicitly.
-
128. SCL-006 - Scale-up SCL-006 Higher-voltage variants shall be assessed for isolation and precharge requirements.
-
129. SCL-007 - Scale-up SCL-007 Variants shall reuse requirement/test templates only after applicability review.
-
130. SCL-008 - Scale-up SCL-008 Series-connected modules shall be validated as one coordinated pack protection system.
The product shall be serviceable using documented diagnostics and replaceable assemblies.
-
57. MEC-007 - Mechanical MEC-007 Serviceable components shall be accessible without disturbing cell terminals unintentionally.
The product shall meet the environmental and mechanical needs of its intended use.
-
19. SYS-009 - System SYS-009 The pack shall comply with an approved system operating envelope.
-
23. CEL-003 - Cell CEL-003 The design shall prevent cell operation outside supplier charge temperature limits.
-
24. CEL-004 - Cell CEL-004 The design shall prevent cell operation outside supplier discharge temperature limits.
-
27. CEL-007 - Cell CEL-007 Cell compression and orientation shall conform to supplier mechanical limits.
-
35. ELE-008 - Electrical ELE-008 PCB creepage, clearance and trace geometry shall meet the approved design rules.
-
52. MEC-002 - Mechanical MEC-002 Cell restraints shall comply with the manufacturer compression limits.
-
54. MEC-004 - Mechanical MEC-004 The enclosure shall withstand the approved static mounting loads.
-
83. SIM-008 - Simulation SIM-008 The structural solver shall support mesh convergence assessment.
-
-
55. MEC-005 - Mechanical MEC-005 The mounting design shall avoid unacceptable resonances in the operational vibration profile.
-
82. SIM-007 - Simulation SIM-007 The structural model shall support eigenfrequency/modal analysis.
-
-
58. MEC-008 - Mechanical MEC-008 Mechanical BOM mass shall match CAD estimate within the approved discrepancy limit.
-
59. MEC-009 - Mechanical MEC-009 Critical dimensions and tolerances shall be present in manufacturing drawings.
-
The project shall support independent review and controlled engineering releases.
-
1. STK-001 - Stakeholder STK-001 The product shall provide a replaceable 12.8 V nominal rechargeable energy source.
The V1 pack shall contain four LFP cells connected in series.
-
21. CEL-001 - Cell CEL-001 Each cell shall be traceable to an approved manufacturer and part number.
-
22. CEL-002 - Cell CEL-002 The selected cell shall provide at least 20 Ah nominal capacity under its specified conditions.
-
25. CEL-005 - Cell CEL-005 Cell model parameters shall identify manufacturer, chemistry, revision and test conditions.
-
26. CEL-006 - Cell CEL-006 Cell selection shall include a defined matching and incoming quality procedure.
-
51. MEC-001 - Mechanical MEC-001 The pack shall secure four cells in the declared CAD orientation.
-
70. CAD-003 - CAD CAD-003 Each CAD cell shall reference an approved part geometry and tolerance set.
-
1. STK-001 - Stakeholder STK-001 The product shall provide a replaceable 12.8 V nominal rechargeable energy source.
The V1 reference energy shall be 256 Wh nominal.
-
37. ELE-010 - Electrical ELE-010 Battery positive and negative polarity shall be unambiguous at external terminals.
-
71. CAD-004 - CAD CAD-004 The CAD assembly shall include terminals, busbars, BMS board, restraints and enclosure.
-
-
2. STK-002 - Stakeholder STK-002 The product shall support an agreed load and charger envelope.
The V1 pack shall support 20 A continuous discharge at the specified ambient and SOC.
-
60. THM-001 - Thermal THM-001 The thermal model shall represent resistive losses in cells and power path.
-
61. THM-002 - Thermal THM-002 The thermal model shall represent ambient convection and thermal contact paths.
-
62. THM-003 - Thermal THM-003 Thermal response shall be estimated for nominal load and agreed duty cycle.
-
63. THM-004 - Thermal THM-004 The hottest measured cell location shall be included in a validation plan.
-
64. THM-005 - Thermal THM-005 Thermal simulation accuracy shall be assessed against measured pack temperatures.
-
81. SIM-006 - Simulation SIM-006 The simulation pipeline shall support parameter calibration without overwriting original measurement data.
-
-
2. STK-002 - Stakeholder STK-002 The product shall support an agreed load and charger envelope.
The V1 pack shall support 10 A charging where the cell supplier permits.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
The pack shall interrupt charge/discharge according to the approved protection state table.
-
28. ELE-001 - Electrical ELE-001 The system shall measure every series-cell voltage independently.
-
41. FW-003 - Firmware FW-003 The firmware shall acquire and validate per-cell voltage samples.
-
-
29. ELE-002 - Electrical ELE-002 Cell voltage measurement error shall remain within the approved error budget.
-
30. ELE-003 - Electrical ELE-003 Pack current shall be measured in both charge and discharge directions.
-
42. FW-004 - Firmware FW-004 The firmware shall maintain a signed coulomb-counting current integral.
-
-
31. ELE-004 - Electrical ELE-004 The system shall detect an open cell-sense lead or enter a defined safe state.
-
36. ELE-009 - Electrical ELE-009 The BMS shall support a documented balancing strategy.
-
44. FW-006 - Firmware FW-006 The firmware shall inhibit balancing under disallowed thermal/electrical states.
-
67. THM-008 - Thermal THM-008 Cell balancing heat shall be represented in BMS thermal budget.
-
-
38. ELE-011 - Electrical ELE-011 BMS power consumption shall remain within an approved storage and standby budget.
-
39. FW-001 - Firmware FW-001 The firmware shall implement explicit INIT, IDLE, CHARGE, DISCHARGE, FAULT and SLEEP states.
-
40. FW-002 - Firmware FW-002 The firmware shall not override autonomous hardware protection to enable unsafe current.
-
45. FW-007 - Firmware FW-007 The firmware shall retain a fault cause across a reset when specified by fault policy.
-
46. FW-008 - Firmware FW-008 The firmware shall detect stalled critical tasks through watchdog supervision.
-
49. FW-011 - Firmware FW-011 The firmware shall detect stale or invalid temperature data.
-
65. THM-006 - Thermal THM-006 The BMS shall block charging outside the permitted cell thermal range.
-
66. THM-007 - Thermal THM-007 The BMS shall block discharge outside the permitted cell thermal range.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
Pack overcurrent/short-circuit protection shall not depend on a cloud connection.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
The pack shall incorporate a coordinated fuse and electronic protection concept.
-
32. ELE-005 - Electrical ELE-005 Protection switches shall withstand approved continuous, pulse and fault operating cases.
-
33. ELE-006 - Electrical ELE-006 The battery shall have a fuse coordinated with conductor and fault energy limits.
-
53. MEC-003 - Mechanical MEC-003 Electrical insulation shall prevent accidental busbar-enclosure contact in all specified tolerances.
-
75. CAD-008 - CAD CAD-008 CAD automation shall detect electrical/physical clearance rule violations.
-
-
56. MEC-006 - Mechanical MEC-006 Busbar fastening shall use controlled fastener and torque specifications.
-
118. MFG-002 - Manufacturing MFG-002 Pack terminal, fuse and busbar assembly shall have prescribed inspection checks.
-
2. STK-002 - Stakeholder STK-002 The product shall support an agreed load and charger envelope.
The pack shall expose a defined service interface for diagnostics.
-
34. ELE-007 - Electrical ELE-007 Diagnostic connector pinout shall be keyed and defined.
-
43. FW-005 - Firmware FW-005 The firmware shall expose versioned diagnostic telemetry.
-
47. FW-009 - Firmware FW-009 The firmware shall reject malformed or unauthorized configuration commands.
-
50. FW-012 - Firmware FW-012 The firmware shall support a controlled calibration data procedure.
-
9. STK-009 - Stakeholder STK-009 The product shall meet the environmental and mechanical needs of its intended use.
The pack shall comply with an approved system operating envelope.
-
23. CEL-003 - Cell CEL-003 The design shall prevent cell operation outside supplier charge temperature limits.
-
24. CEL-004 - Cell CEL-004 The design shall prevent cell operation outside supplier discharge temperature limits.
-
27. CEL-007 - Cell CEL-007 Cell compression and orientation shall conform to supplier mechanical limits.
-
35. ELE-008 - Electrical ELE-008 PCB creepage, clearance and trace geometry shall meet the approved design rules.
-
52. MEC-002 - Mechanical MEC-002 Cell restraints shall comply with the manufacturer compression limits.
-
54. MEC-004 - Mechanical MEC-004 The enclosure shall withstand the approved static mounting loads.
-
83. SIM-008 - Simulation SIM-008 The structural solver shall support mesh convergence assessment.
-
-
55. MEC-005 - Mechanical MEC-005 The mounting design shall avoid unacceptable resonances in the operational vibration profile.
-
82. SIM-007 - Simulation SIM-007 The structural model shall support eigenfrequency/modal analysis.
-
-
58. MEC-008 - Mechanical MEC-008 Mechanical BOM mass shall match CAD estimate within the approved discrepancy limit.
-
59. MEC-009 - Mechanical MEC-009 Critical dimensions and tolerances shall be present in manufacturing drawings.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Every completed system test shall identify the tested hardware and firmware revisions.
-
11. SYS-001 - System SYS-001 The V1 pack shall contain four LFP cells connected in series.
-
1. STK-001 - Stakeholder STK-001 The product shall provide a replaceable 12.8 V nominal rechargeable energy source.
-
Each cell shall be traceable to an approved manufacturer and part number.
-
11. SYS-001 - System SYS-001 The V1 pack shall contain four LFP cells connected in series.
-
1. STK-001 - Stakeholder STK-001 The product shall provide a replaceable 12.8 V nominal rechargeable energy source.
-
The selected cell shall provide at least 20 Ah nominal capacity under its specified conditions.
-
19. SYS-009 - System SYS-009 The pack shall comply with an approved system operating envelope.
-
9. STK-009 - Stakeholder STK-009 The product shall meet the environmental and mechanical needs of its intended use.
-
The design shall prevent cell operation outside supplier charge temperature limits.
-
19. SYS-009 - System SYS-009 The pack shall comply with an approved system operating envelope.
-
9. STK-009 - Stakeholder STK-009 The product shall meet the environmental and mechanical needs of its intended use.
-
The design shall prevent cell operation outside supplier discharge temperature limits.
-
11. SYS-001 - System SYS-001 The V1 pack shall contain four LFP cells connected in series.
-
1. STK-001 - Stakeholder STK-001 The product shall provide a replaceable 12.8 V nominal rechargeable energy source.
-
Cell model parameters shall identify manufacturer, chemistry, revision and test conditions.
-
11. SYS-001 - System SYS-001 The V1 pack shall contain four LFP cells connected in series.
-
1. STK-001 - Stakeholder STK-001 The product shall provide a replaceable 12.8 V nominal rechargeable energy source.
-
Cell selection shall include a defined matching and incoming quality procedure.
-
19. SYS-009 - System SYS-009 The pack shall comply with an approved system operating envelope.
-
9. STK-009 - Stakeholder STK-009 The product shall meet the environmental and mechanical needs of its intended use.
-
Cell compression and orientation shall conform to supplier mechanical limits.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
The system shall measure every series-cell voltage independently.
-
41. FW-003 - Firmware FW-003 The firmware shall acquire and validate per-cell voltage samples.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
Cell voltage measurement error shall remain within the approved error budget.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
Pack current shall be measured in both charge and discharge directions.
-
42. FW-004 - Firmware FW-004 The firmware shall maintain a signed coulomb-counting current integral.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
The system shall detect an open cell-sense lead or enter a defined safe state.
-
17. SYS-007 - System SYS-007 The pack shall incorporate a coordinated fuse and electronic protection concept.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
Protection switches shall withstand approved continuous, pulse and fault operating cases.
-
17. SYS-007 - System SYS-007 The pack shall incorporate a coordinated fuse and electronic protection concept.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
The battery shall have a fuse coordinated with conductor and fault energy limits.
-
18. SYS-008 - System SYS-008 The pack shall expose a defined service interface for diagnostics.
-
2. STK-002 - Stakeholder STK-002 The product shall support an agreed load and charger envelope.
-
Diagnostic connector pinout shall be keyed and defined.
-
19. SYS-009 - System SYS-009 The pack shall comply with an approved system operating envelope.
-
9. STK-009 - Stakeholder STK-009 The product shall meet the environmental and mechanical needs of its intended use.
-
PCB creepage, clearance and trace geometry shall meet the approved design rules.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
The BMS shall support a documented balancing strategy.
-
44. FW-006 - Firmware FW-006 The firmware shall inhibit balancing under disallowed thermal/electrical states.
-
67. THM-008 - Thermal THM-008 Cell balancing heat shall be represented in BMS thermal budget.
-
12. SYS-002 - System SYS-002 The V1 reference energy shall be 256 Wh nominal.
-
1. STK-001 - Stakeholder STK-001 The product shall provide a replaceable 12.8 V nominal rechargeable energy source.
-
Battery positive and negative polarity shall be unambiguous at external terminals.
-
71. CAD-004 - CAD CAD-004 The CAD assembly shall include terminals, busbars, BMS board, restraints and enclosure.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
BMS power consumption shall remain within an approved storage and standby budget.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
The firmware shall implement explicit INIT, IDLE, CHARGE, DISCHARGE, FAULT and SLEEP states.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
The firmware shall not override autonomous hardware protection to enable unsafe current.
-
28. ELE-001 - Electrical ELE-001 The system shall measure every series-cell voltage independently.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
-
The firmware shall acquire and validate per-cell voltage samples.
-
30. ELE-003 - Electrical ELE-003 Pack current shall be measured in both charge and discharge directions.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
-
The firmware shall maintain a signed coulomb-counting current integral.
-
18. SYS-008 - System SYS-008 The pack shall expose a defined service interface for diagnostics.
-
2. STK-002 - Stakeholder STK-002 The product shall support an agreed load and charger envelope.
-
The firmware shall expose versioned diagnostic telemetry.
-
36. ELE-009 - Electrical ELE-009 The BMS shall support a documented balancing strategy.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
-
The firmware shall inhibit balancing under disallowed thermal/electrical states.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
The firmware shall retain a fault cause across a reset when specified by fault policy.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
The firmware shall detect stalled critical tasks through watchdog supervision.
-
18. SYS-008 - System SYS-008 The pack shall expose a defined service interface for diagnostics.
-
2. STK-002 - Stakeholder STK-002 The product shall support an agreed load and charger envelope.
-
The firmware shall reject malformed or unauthorized configuration commands.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Every firmware release shall retain build provenance and checksum.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
The firmware shall detect stale or invalid temperature data.
-
18. SYS-008 - System SYS-008 The pack shall expose a defined service interface for diagnostics.
-
2. STK-002 - Stakeholder STK-002 The product shall support an agreed load and charger envelope.
-
The firmware shall support a controlled calibration data procedure.
-
11. SYS-001 - System SYS-001 The V1 pack shall contain four LFP cells connected in series.
-
1. STK-001 - Stakeholder STK-001 The product shall provide a replaceable 12.8 V nominal rechargeable energy source.
-
The pack shall secure four cells in the declared CAD orientation.
-
19. SYS-009 - System SYS-009 The pack shall comply with an approved system operating envelope.
-
9. STK-009 - Stakeholder STK-009 The product shall meet the environmental and mechanical needs of its intended use.
-
Cell restraints shall comply with the manufacturer compression limits.
-
17. SYS-007 - System SYS-007 The pack shall incorporate a coordinated fuse and electronic protection concept.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
Electrical insulation shall prevent accidental busbar-enclosure contact in all specified tolerances.
-
75. CAD-008 - CAD CAD-008 CAD automation shall detect electrical/physical clearance rule violations.
-
19. SYS-009 - System SYS-009 The pack shall comply with an approved system operating envelope.
-
9. STK-009 - Stakeholder STK-009 The product shall meet the environmental and mechanical needs of its intended use.
-
The enclosure shall withstand the approved static mounting loads.
-
83. SIM-008 - Simulation SIM-008 The structural solver shall support mesh convergence assessment.
-
19. SYS-009 - System SYS-009 The pack shall comply with an approved system operating envelope.
-
9. STK-009 - Stakeholder STK-009 The product shall meet the environmental and mechanical needs of its intended use.
-
The mounting design shall avoid unacceptable resonances in the operational vibration profile.
-
82. SIM-007 - Simulation SIM-007 The structural model shall support eigenfrequency/modal analysis.
-
17. SYS-007 - System SYS-007 The pack shall incorporate a coordinated fuse and electronic protection concept.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
Busbar fastening shall use controlled fastener and torque specifications.
-
8. STK-008 - Stakeholder STK-008 The product shall be serviceable using documented diagnostics and replaceable assemblies.
Serviceable components shall be accessible without disturbing cell terminals unintentionally.
-
19. SYS-009 - System SYS-009 The pack shall comply with an approved system operating envelope.
-
9. STK-009 - Stakeholder STK-009 The product shall meet the environmental and mechanical needs of its intended use.
-
Mechanical BOM mass shall match CAD estimate within the approved discrepancy limit.
-
19. SYS-009 - System SYS-009 The pack shall comply with an approved system operating envelope.
-
9. STK-009 - Stakeholder STK-009 The product shall meet the environmental and mechanical needs of its intended use.
-
Critical dimensions and tolerances shall be present in manufacturing drawings.
-
13. SYS-003 - System SYS-003 The V1 pack shall support 20 A continuous discharge at the specified ambient and SOC.
-
2. STK-002 - Stakeholder STK-002 The product shall support an agreed load and charger envelope.
-
The thermal model shall represent resistive losses in cells and power path.
-
13. SYS-003 - System SYS-003 The V1 pack shall support 20 A continuous discharge at the specified ambient and SOC.
-
2. STK-002 - Stakeholder STK-002 The product shall support an agreed load and charger envelope.
-
The thermal model shall represent ambient convection and thermal contact paths.
-
13. SYS-003 - System SYS-003 The V1 pack shall support 20 A continuous discharge at the specified ambient and SOC.
-
2. STK-002 - Stakeholder STK-002 The product shall support an agreed load and charger envelope.
-
Thermal response shall be estimated for nominal load and agreed duty cycle.
-
13. SYS-003 - System SYS-003 The V1 pack shall support 20 A continuous discharge at the specified ambient and SOC.
-
2. STK-002 - Stakeholder STK-002 The product shall support an agreed load and charger envelope.
-
The hottest measured cell location shall be included in a validation plan.
-
13. SYS-003 - System SYS-003 The V1 pack shall support 20 A continuous discharge at the specified ambient and SOC.
-
2. STK-002 - Stakeholder STK-002 The product shall support an agreed load and charger envelope.
-
Thermal simulation accuracy shall be assessed against measured pack temperatures.
-
81. SIM-006 - Simulation SIM-006 The simulation pipeline shall support parameter calibration without overwriting original measurement data.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
The BMS shall block charging outside the permitted cell thermal range.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
The BMS shall block discharge outside the permitted cell thermal range.
-
36. ELE-009 - Electrical ELE-009 The BMS shall support a documented balancing strategy.
-
15. SYS-005 - System SYS-005 The pack shall interrupt charge/discharge according to the approved protection state table.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
-
Cell balancing heat shall be represented in BMS thermal budget.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
The master model shall generate the declared pack geometry from controlled parameters.
-
7. STK-007 - Stakeholder STK-007 The product family shall support 24 V, 48 V and 72 V-class variants through controlled reuse.
The CAD generator shall support independent series count and cell dimensions within permitted families.
-
11. SYS-001 - System SYS-001 The V1 pack shall contain four LFP cells connected in series.
-
1. STK-001 - Stakeholder STK-001 The product shall provide a replaceable 12.8 V nominal rechargeable energy source.
-
Each CAD cell shall reference an approved part geometry and tolerance set.
-
37. ELE-010 - Electrical ELE-010 Battery positive and negative polarity shall be unambiguous at external terminals.
-
12. SYS-002 - System SYS-002 The V1 reference energy shall be 256 Wh nominal.
-
1. STK-001 - Stakeholder STK-001 The product shall provide a replaceable 12.8 V nominal rechargeable energy source.
-
-
The CAD assembly shall include terminals, busbars, BMS board, restraints and enclosure.
-
6. STK-006 - Stakeholder STK-006 The project shall maintain a costed production BOM and approved alternatives.
CAD part quantities shall be reconciled with the engineering BOM.
-
4. STK-004 - Stakeholder STK-004 The engineering platform shall allow remote access to released engineering designs.
The build pipeline shall publish a browser-inspectable 3D derivative.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
CAD outputs shall identify generator version and input parameter revision.
-
53. MEC-003 - Mechanical MEC-003 Electrical insulation shall prevent accidental busbar-enclosure contact in all specified tolerances.
-
17. SYS-007 - System SYS-007 The pack shall incorporate a coordinated fuse and electronic protection concept.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
-
CAD automation shall detect electrical/physical clearance rule violations.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
The digital twin shall expose a 4-cell electrical equivalent-circuit model.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Each model run shall record parameter set, solver version and boundary conditions.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
The simulator shall distinguish model predictions from measured test data.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
The pack model shall report voltage, current, SOC, power and accumulated energy.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
The pack model shall evaluate per-cell imbalance.
-
64. THM-005 - Thermal THM-005 Thermal simulation accuracy shall be assessed against measured pack temperatures.
-
13. SYS-003 - System SYS-003 The V1 pack shall support 20 A continuous discharge at the specified ambient and SOC.
-
2. STK-002 - Stakeholder STK-002 The product shall support an agreed load and charger envelope.
-
-
The simulation pipeline shall support parameter calibration without overwriting original measurement data.
-
55. MEC-005 - Mechanical MEC-005 The mounting design shall avoid unacceptable resonances in the operational vibration profile.
-
19. SYS-009 - System SYS-009 The pack shall comply with an approved system operating envelope.
-
9. STK-009 - Stakeholder STK-009 The product shall meet the environmental and mechanical needs of its intended use.
-
-
The structural model shall support eigenfrequency/modal analysis.
-
54. MEC-004 - Mechanical MEC-004 The enclosure shall withstand the approved static mounting loads.
-
19. SYS-009 - System SYS-009 The pack shall comply with an approved system operating envelope.
-
9. STK-009 - Stakeholder STK-009 The product shall meet the environmental and mechanical needs of its intended use.
-
-
The structural solver shall support mesh convergence assessment.
-
4. STK-004 - Stakeholder STK-004 The engineering platform shall allow remote access to released engineering designs.
Interactive simulation shall return a useful lightweight response within the target UI budget.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Invalid model parameters shall be rejected before execution.
-
4. STK-004 - Stakeholder STK-004 The engineering platform shall allow remote access to released engineering designs.
Authorized users shall access released projects through modern browsers.
-
4. STK-004 - Stakeholder STK-004 The engineering platform shall allow remote access to released engineering designs.
Project access shall require authenticated identity and role authorization.
-
4. STK-004 - Stakeholder STK-004 The engineering platform shall allow remote access to released engineering designs.
Large CAD and simulation artifacts shall be stored in Google Cloud Storage.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Requirement documents shall be managed as Git-versioned text sources.
-
4. STK-004 - Stakeholder STK-004 The engineering platform shall allow remote access to released engineering designs.
The UI shall display read-only released CAD model derivatives.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Each simulation result shall reference immutable input and executable versions.
-
4. STK-004 - Stakeholder STK-004 The engineering platform shall allow remote access to released engineering designs.
Long simulation jobs shall execute outside synchronous web requests.
-
4. STK-004 - Stakeholder STK-004 The engineering platform shall allow remote access to released engineering designs.
Cloud storage objects shall be recoverable under the approved backup policy.
-
4. STK-004 - Stakeholder STK-004 The engineering platform shall allow remote access to released engineering designs.
Remote application secrets shall not be embedded in downloaded browser assets.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
The system shall maintain immutable release manifests.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
The UI shall link each failed test to its governing requirement.
-
4. STK-004 - Stakeholder STK-004 The engineering platform shall allow remote access to released engineering designs.
The platform shall refuse hazardous remote physical-bench actuation without local enable.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
The platform shall preserve source measurements separately from derived simulation results.
-
4. STK-004 - Stakeholder STK-004 The engineering platform shall allow remote access to released engineering designs.
Users shall see run state, errors, and diagnostic references for failed jobs.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Every approved engineering requirement shall have a verification method and acceptance criterion.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Safety-critical requirements shall have a hazard link and review approval.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Test cases shall identify setup, stimuli, expected result, actual result and artifacts.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Verification results shall distinguish Passed, Failed, Blocked and Not Run.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
The system shall prohibit release on unresolved critical verification failures.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Test equipment shall be linked to calibration status and uncertainty.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Requirement changes after baseline shall trigger impact analysis.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
System validation shall be distinguished from specification verification.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Fault injection shall never energize an unguarded hazardous battery bench remotely.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Regression suites shall run on every controlled software change.
-
6. STK-006 - Stakeholder STK-006 The project shall maintain a costed production BOM and approved alternatives.
Every approved purchasable part shall have a unique ID and revision.
-
6. STK-006 - Stakeholder STK-006 The project shall maintain a costed production BOM and approved alternatives.
The BOM shall separate cell, BMS, enclosure, harness and assembly cost.
-
6. STK-006 - Stakeholder STK-006 The project shall maintain a costed production BOM and approved alternatives.
Unit cost shall be calculated at prototype, 100 and 10000-unit quantities.
-
6. STK-006 - Stakeholder STK-006 The project shall maintain a costed production BOM and approved alternatives.
Approved alternates shall preserve form-fit-function and qualification evidence.
-
6. STK-006 - Stakeholder STK-006 The project shall maintain a costed production BOM and approved alternatives.
The platform shall flag obsolete or single-source critical parts.
-
6. STK-006 - Stakeholder STK-006 The project shall maintain a costed production BOM and approved alternatives.
The system shall calculate estimated landed cost using separated assumptions.
-
6. STK-006 - Stakeholder STK-006 The project shall maintain a costed production BOM and approved alternatives.
Any BOM cost comparison shall identify assumptions and quote validity.
-
6. STK-006 - Stakeholder STK-006 The project shall maintain a costed production BOM and approved alternatives.
The pack shall have a defined assembly process with controlled order of operations.
-
17. SYS-007 - System SYS-007 The pack shall incorporate a coordinated fuse and electronic protection concept.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
-
Pack terminal, fuse and busbar assembly shall have prescribed inspection checks.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Each assembled pack shall carry serial and test result identity.
-
6. STK-006 - Stakeholder STK-006 The project shall maintain a costed production BOM and approved alternatives.
The project shall calculate yield-adjusted production BOM cost.
-
3. STK-003 - Stakeholder STK-003 The product shall prevent hazardous electrical and thermal operating states.
Release documents shall include safe shipping and handling requirements.
-
5. STK-005 - Stakeholder STK-005 The platform shall trace design decisions to requirements and verification evidence.
Firmware programming and configuration shall be logged during end-of-line test.
-
7. STK-007 - Stakeholder STK-007 The product family shall support 24 V, 48 V and 72 V-class variants through controlled reuse.
The family architecture shall separate hardware-dependent protection from portable firmware logic.
-
7. STK-007 - Stakeholder STK-007 The product family shall support 24 V, 48 V and 72 V-class variants through controlled reuse.
The platform shall reject designs where maximum pack voltage exceeds rated components.
-
7. STK-007 - Stakeholder STK-007 The product family shall support 24 V, 48 V and 72 V-class variants through controlled reuse.
The 8S variant shall receive its own sensing and power protection review.
-
7. STK-007 - Stakeholder STK-007 The product family shall support 24 V, 48 V and 72 V-class variants through controlled reuse.
The 16S variant shall receive separate voltage/clearance and protection validation.
-
7. STK-007 - Stakeholder STK-007 The product family shall support 24 V, 48 V and 72 V-class variants through controlled reuse.
The 72 V-class variant shall define nominal and absolute maximum voltage explicitly.
-
7. STK-007 - Stakeholder STK-007 The product family shall support 24 V, 48 V and 72 V-class variants through controlled reuse.
Higher-voltage variants shall be assessed for isolation and precharge requirements.
-
7. STK-007 - Stakeholder STK-007 The product family shall support 24 V, 48 V and 72 V-class variants through controlled reuse.
Variants shall reuse requirement/test templates only after applicability review.
-
7. STK-007 - Stakeholder STK-007 The product family shall support 24 V, 48 V and 72 V-class variants through controlled reuse.
Series-connected modules shall be validated as one coordinated pack protection system.