ENGINEERING PLATFORM / V1 REFERENCE

Simulation & CAD

Understand the pack. Trace the decisions. Build the evidence.

DRAFT BASELINE
M0 · Uncalibrated reference. Illustrative simulation and geometry. Physical qualification has not been performed.

From cell terminals to vehicle response.

48 V-class LFP · 16S / 51.2 V nominal · 40 Ah assumption · 58.4 V upper reference. Explore the pack, electronics and external power stage together.

Vehicle & input conditions

M0 / 16S

40 A discharge · 20 A charge · 15 A regen. Ideal contactors and immediate protection. No hardware commands.

SIMULATION OUTPUTS

Ready to simulate

Choose inputs and run. Charge mode needs a plugged-in charger; traction needs key on and charger unplugged.

A 100 Ω precharge path charges a 2.2 mF external DC link before the main contactor closes. Switched bleed is off during precharge.

ELECTRICAL TOPOLOGY / LIVE COMMANDS

Overall BMS & traction circuit

Download diagram

Select a component to locate it in CAD. Green highlights commanded closed/active paths. The model does not verify actual contact positions. Charger, inverter, DC-link and switched bleed are external vehicle equipment.

KICAD / ELECTRONICS

16S sensing & interface PCB

REVIEW REFERENCE
Routed four-layer BMS sensing PCB

76 components: BQ7695202 AFE, 17 input resistors and 16 differential cell filters, shunt filter, 16:1 NTC mux and dividers, regulators’ bypass capacitors and host headers.

Traction current stays off this board. The external MCU, CAN transceiver, auxiliary supply and fail-safe coil-driver circuits are separate design work. No firmware or production release is included.

Loading native checks…

CAD / CONNECTIVITY AUDIT

What was found and checked

Loading audit…

The earlier 4S concept contains 31 wire-end gaps, five support/interface gaps and four sensor-pad intrusions. Its original audit is retained. This separate 16S revision uses explicit conductive terminals and exports local-origin STEP geometry plus assembly placement for each element.

Endpoint coincidence does not prove full electrical correctness. Cable clashes, insulation thickness, creepage, lugs, torque, current ratings, cell compression, thermal propagation, pressure relief and IP65 qualification remain open. The original 4S model is retained as a legacy reference.

12.8 V4 cells in series
256 Wh20 Ah reference capacity
70 %Initial condition
25 °CSingle thermal node

SOFTWARE IN THE LOOP

Operating conditions

LFP / 4S

Positive: discharge · Negative: charge

Ideal protection response. Thresholds are educational settings. No hardware is connected.

PACK ARCHITECTURE

Interactive pack assembly

Battery pack / interactive CAD
LFP cells Concept interconnects
How the BMS responds

The BMS measures individual cells, current and temperature. Charging and discharging can be interrupted independently.

Run a scenario to inspect the protection state.

CAD / MODEL / REQUIREMENTS / EVIDENCE

Select a component

PROPOSED ALLOCATION

Run a simulation

No hardware is connected.

Related requirements

Planned verification

Purchasing groups

Links are proposed engineering allocations. A planned test link is not a passed test. Purchasing groups still need detailed component lines.

MODEL RESPONSE

Time history

Scrub the run to update CAD status, measurements and the chart cursor.

Run a simulation to generate samples.

MECHANICAL EXPLORER

Mounting & vibration

M0 / SDOF

Linear single-mass model; no FEM analysis or qualification profile.

Build, connect and inspect the BMS.

Executable discrete signal blocks for sensing, protection, current interruption and state reporting. The battery and thermal states advance between graph evaluations. Settings apply to this software model only.

Not run

Loading block library...

Drag a block header to arrange it. Click an output circle, then an input circle, to connect compatible signals.

Displayed signals belong to the last completed run. Rerun after changing parameters or wiring.

BLOCK INSPECTOR

Select a block

Signal values

No run yet.

SIGNAL SCOPE

Inspect the execution

Run the model to generate signals.

STRICTDOC / SOURCE OF TRUTH

Requirement baseline

Open StrictDoc ↗

ID / domainRequirement & acceptancePlanned testsState

Select a requirement ID to inspect downstream parent links.

Evidence before approval

These are recovered draft test procedures. Software regression results remain separate from physical test evidence.

Draft test procedures

Test / requirementProcedureExpected resultStatus

Hazard register

HazardControlsSeverity / state

PROCUREMENT / INR

Reference bill of materials

UNQUOTED

Part IDAssembly / descriptionQuantityUnit costLine total

CAD component allocations

Select a part to inspect it in the 3D assembly. BOM IDs below refer to purchasing groups.

CAD partFunctionRequirementsBOM group

Blank quotes remain unknown. Supplier specifications, alternatives, landed costs and production price breaks require sourcing.

Develop through the V-model

Stakeholder needs → system requirements → subsystem design → implementation → unit, integration and system evidence.

Decisions to close

16S COMPONENT ANATOMY / REV 0.3

Explore the solid CAD assembly

Open interactive CAD ↗

Cells, temperature sensors, voltage taps, shunt and Kelvin wiring, BMS, busbars, switches and the IP65 enclosure concept. Rotate, explode, select components and download STEP.